3.1. Electrical data
Type
Temperature class
Type of current
Rated voltage
Rated current
Holding power
3.1.1.
Electrical connection
Marking
Execution
A *
Permanently installed rubber sheathed cable of
Type H05 RN-F3G0.75
Terminal box with threaded nipple M20 x 1.5,
without fuse
L
Terminal box with threaded nipple NPT 1/2,
without fuse
Terminal box with threaded nipple G 1/2, without
fuse
Terminal box with threaded nipple M20 x 1.5 and
fuse
K ***
Terminal box with threaded nipple NPT 1/2 and
fuse
Terminal box with threaded nipple G 1/2 and fuse
* The connecting cable of solenoid Type 6..- must be laid permanently
such that it is adequately protected from mechanical damage
** Cable bushing to separate Design Inspection Certificate
*** Fuse/contactor to separate Design Inspection Certificate
NOTES!
The minimum rated cross-section of the conductor strands is
0.75 mm
.
2
64.-....-...-.
T4
universal
12 ... 240 V
0.58 ... 0.034 A
7 W
** Terminal box with cable bushing M20 x
1.5, without fuse
** Terminal box with cable bushing M20 x
1.5 and fuse
65.-....-...-.
T5
universal
12 ... 240 V
0.42 ... 0.025 A
5 W
Internal code
none
JA02
JA08
JA09
JA10
JA01
JA05
JA06
JA07
03 ATEX1089 X - 13