4
Technical daTa
The following values are indicated on the type label:
• Voltage (tolerance ±10 %) and current type
• Coil power consumption (active power in W, at operating
temperature)
• Pressure range
• Operating principle
• Orifice
• Port connection
• Valve body material (MS = Brass, VA = Stainless steel)
• Seal material (FKM, EPDM, NBR)
4.1 conformity
The solenoid valve Type 6011 conforms to the EC directives according
to the EC Declaration of Conformity (if applicable).
4.2 standards
The applied standards, which are used to demonstrate compliance with
the EC Directives, are listed in the EC type test certificate and/or the EC
Declaration of Conformity (if applicable).
4.4 Mechanical data
Dimensions
see data sheet
Valve body material
Type 6011:
Type 6011A: Brass, Stainless steel 1.4305
Sealing material
FKM
4.5 fluidic data
Circuit functions (CF)
2 (A)
A
2/2-way valve, direct-acting, closed in
(NC)
rest position
1 (P)
Pressure range
see type label
Port connections
Type 6011:
Type 6011A: G1/8, Flange
english
6
4.7 electrical data
Connections
DIN EN 175301-803 shape C:
for cable plug Type 2506
DIN 43650 shape B:
for cable plug Type 2507
Wire connection on request
Operating voltage
Type 6011: 24 V DC ±10 % -
Type 6011A: 24 V DC ±10 % -
Voltage tolerance
±10 %
Nominal power
4 W
Nominal operating mode long-term operation, ED 100 %
for block assembly:
2 W long-term operation on request
4 W intermittent operation 60 % (30 min)
Brass, Polyamide (PA),
Stainless steel 1.4305
M5, G1/8, Flange
24 V / 50 Hz
110 / 230 V / 50 Hz
24 V / 50 Hz
230 V / 50 Hz
4.3 operating conditions
Warning!
Heat sources or temperature fluctuations may cause malfunc-
tions or leaks.
▶ When using the device outside, protect it from the effects of the
weather.
▶ Avoid heat sources which may cause the permitted temperature
range to be exceeded.
Ambient temperature
-10...+55 °C
Medium temperature
-10...+55 °C
Media
neutral, gaseous and liquid media, which do
not attack body and sealing materials (see
resistance table at www.burkert.com)
Viscosity
max. 21 mm²/s
Degree of protection
IP65 in accordance EN 60529 with cable
plug
english
4.6 Type label (example)
Orifice
Circuit function
Type
6011 A 1,2 FKM MS
G1/8 PN 0 - 10 bar
24V
50Hz
00450000
Identification number
CE-sign, if applicable
Voltage, Frequency, Output
Port connection,
Pressure range
5
insTallaTion
Danger!
Risk of injury from high pressure in the system or device.
▶ Before working on the system or device, switch off the pressure
and vent and drain lines.
Risk of injury due to electric shock.
▶ Before working on the system or device, switch off the power sup-
ply and secure to prevent reactivation.
▶ Observe applicable accident prevention and safety regulations for
electrical equipment.
Warning!
Risk of injury from improper installation.
▶ Installation may be carried out only by trained technicians and with
the appropriate tools.
▶ Secure system against unintentional activation.
▶ Following installation, ensure a controlled restart.
english
Type 6011
5
Sealing material
Valve body material
4W
WXXXX
7