8030
4.3 Electrical connection
Always ensure the power supply is switched off before working on the device.
The connector must be plugged out.
- Use cables with an operating temperature suited with the
process conditions.
- For normal operating conditions the measuring signal can be
transmitted by a shielded cable of 0,75 mm
- The cable must not be installed in combination with carrying lines
with a higher voltage or frequency.
- If a combined installation cannot be avoided, a minimum space of
30 cm should be respected.
- Use a high quality voltage supply (filtered and regulated).
install an appropriate fuse for the power supply.
1
cross section.
2