2.1.7.
Maximum permissible ambient temperature
range
Please observe the maximum permissible ambient temperature range given under
Operating conditions of the coils for each type!
Version
Installation
64.-....-...-.
Individual assembly
65.-....-...-.
Individual assembly
2.1.8.
Use in petrol pumps
DANGER!
Risk of explosion if the device is opened!
•
The valves may only be dismantled by the manufacturer. The always
represent a closed system!
DANGER!
Risk of explosion!
•
When using the devices in petrol pumps for the control of petrol in
category 2, a valve body made of metal (brass, aluminium or stainless
steel) must be employed!
The devices may also be used for the control of petrol in Category 2 when no air
and no oxygen are present in the closed system.
This also applies during start-up and shut-down of the system.
screwed as a block
10 - 03 ATEX1089 X
Block assembly
Block assembly
Maximum permissible ambient
temperature range
-40 °C ... +60 °C
-40 °C ... +45 °C
-40 °C ... +50 °C
-40 °C ... +40 °C
plugged-on