5.
DESCRIPTION
5.1.
Area of application
The 8200 hygienic holder is intended for professional use in
process measurements technology, as a holder for probe with a
12 mm shaft diameter. Depending on the version, the hygienic
holder can either be installed on a weld-in socket with a diameter
of 25 mm or a clamp connection or a 2" (DN50/40) connection
adapted for GEA Tuchenhagen VARINLINE process connections.
5.2.
Available versions
The hygienic holder is available in the following versions:
Process connection
G 1¼" internal thread *
G 1¼" internal thread *
2" (DN50/40) connection
adapted for GEA Tuchen-
hagen VARINLINE process
connections *
Clamp 1½", (dia. 50.5 mm)
* The certificate 3.1 is supplied with the holder.
Type 8200
Description
Specification
Order code
O-ring position
562431
(OP): 25 mm
O-ring position
562432
(OP): 50 mm
Inclination: 15°
562433
Insertion lenght:
558885
33 mm
6.
TECHNICAL DATA
6.1.
Conditions of use
Fluid temperature
135 °C max.
Temperature limits may depend on the
inserted probe. Refer to the relevant
operating instructions. If the temperature
ranges given for the holder and the
inserted probe are different, use the most
restrictive range.
Pressure class
6 bar max.
Pressure limits may depend on the
inserted probe. Refer to the relevant
operating instructions. If the pressure
ranges given for the holder and the
inserted probe are different, use the most
restrictive range.
6.2.
Materials
Part
Material
Body
Stainless steel
O-ring
EPDM (FDA agreement)
English