FUSE CHECK/REPLACEMENT/RESET
Circuit breaker check
1.
Drive the machine on a level ground.
2.
Engage the parking brake.
3.
Turn the ignition key (65) to "O" and remove it.
4.
On the panel (38), check for deactivation of one of the following fuses (Fig. 12):
(A): F1 (30 A), vacuum system
(B): F2 (16 A), filter shaker
(C): F4 (30 A), ignition key
(D): F5 (16 A), engine accessory
(E): F3 (10 A), DustGuard™ system nozzle (optional)
(F): F6 (10 A), working light (optional)
(G): F7, light system (optional)
(H): F8, cab fan (optional)
Reset any deactivated fuse, when the component that caused deactivation has fully cooled down
Fuse check/replacement
1.
Drive the machine on a level ground.
2.
Engage the parking brake.
3.
Turn the ignition key (65) to "O" and remove it.
4.
Open the engine compartment hood (1) by using the unlocking push-button (25).
5.
In the driver's seat area, remove the covers and check the following fuses for integrity (Fig. 13):
(J): F10 (50 A), alternator
Replace any open fuse. Install the cover.
6.
Close the engine compartment hood (1).
30
INSTRUCTIONS FOR USE
A
B
C
G
H
J
Proterra™ - 33019864
E
D
F
Figure 12
P100327LPG
Figure 13
revised 08/2018