Alarm signals
In the event of a working defect, the system informs the user about the type of failure occurred.
The following table summarises the alarms, kind of problem and possible solution:
Display
ALAR 1
BLACK OUT
PROBE
ALAR 2
EXHAUST
HOT
ALAR 3
EXHAUST
FAN
ALAR 4
FAILURE
NO
ALAR 5
LIGHTIN
NO
ALAR 6
PELLET
SAFETY
ALAR 7
THERMAL
FAILURE
ALAR 8
DEPRESS
ERROR
ALAR B
TRIAC
COCLEA
PROBE
ALAR C
WATER
HOT
ALAR D
WATER
PRESS
ALAR E
WATER
SERV
Regular checks should be carried out by the user, who should only contact the Authorized
Assistance Center if no solution is found.
34
Kind of problem
There is no power supply
The smokes sensor is broken or
not connected to the pcb
Smokes temperature too high
Smokes
extractor
blocked
broken
The Boiler cannot start up
This is the first light-up
The pellet boiler switched off
while working
The water temperature exceeds
90°C. The circulating pump is
blocked or there is no water in
the hydraulic system
Obstructed flue
The cochlea loads too much pellet Contact an Authorized Assistance Center
Water probe faulty
Water temperature too high
Water pressure too high
The Boiler has worked for 1300
hours. Supplementary maintenan-
ce required
Solution
As soon as the power supply is back, the Boiler
starts a cooling cycle. After completing the cycle it
starts working automatically
Contact an Authorized Assistance Center
Switch off the Boiler, allow it to cool down and
perform ordinary cleaning. If the problem persists,
contact an Authorized Assistance Center for
cleaning the Boiler and the flue
or
Contact an Authorized Assistance Center
Fill in the tank with pellets
Start up again
Fill in the tank with pellets
Check the power supply on the pump.
Check limestone does not block the pump impe-
ller
Clean the flue or check there are no obstructed
grids near the smokes exhaust
Contact an Authorized Assistance Center
Allow the boiler to cool down. If the problem per-
sists, contact an Authorized Assistance Center and
have the hydraulic system checked
Allow the boiler to cool down. If the problem per-
sists, contact an Authorized Assistance Center and
have the hydraulic system checked
Contact an Authorized Assistance Center