Distance to objects
The boiler should be inspected on all sides, so you
have to keep a distance of at least 40 cm at the
back and sides. It is also recommended to keep the
pellets and all flammable materials at a suitable
distance
40 cm
REMARKS:
- the appliance must be installed by a qualified
technician in possession of the technical and
professional requirements according to the
DM37/2008 that, under its responsibility, to ensure
compliance with the rules of good technique.
- the boiler must be connected to a heating system
and/or to a network of production of sanitary hot
water, consistent with its performance and its
power
- you need to keep in mind all laws and national,
regional, provincial and municipal laws of the
country in which you installed the device
- check that the floor is not flammable: if necessary
use a suitable platform
- in the room where the generator must be
installed to heat must not pre-exist or be installed
with an extractor hood or ventilation ducts of the
collective type.
10
40 cm
Should these devices be located in adjacent
rooms communicating with the installation, and
'prohibited the simultaneous use of the heat
generator, where there is a risk that one of the two
rooms being placed in depression than the other
- it is not permissible to install in bedrooms or
bathrooms
- for hydraulic connections (see next chapter) it is
advisable to use where possible of hoses
- the boiler is equipped with a flue gas fans for the
extraction of exhaust gases and works in depression
with respect to the combustion chamber;
- the boiler works with low flue gas temperatures.
During installation take adequate measures to
prevent the formation of condensation.