Now the upper section to the
heat exchanger is free from
any encumbrance so as to
allow a perfect cleaning.
Following the cleaning of the upper compartment of
the exchange section, store the upper closure cover.
This cover must be closed, as well as with normal
screws, with webbing in ceramic fiber rope to
ensure the watertight closure of the boiler. This
general cleaning should be carried out at the end
of the season in order to facilitate the general
removal of all residues of combustion, without
waiting too long, because with time and humidity
these residues can become compacted. Check the
seal of the ceramic fiber gaskets on the door of
the boiler.
Then clean the flue system especially near the
fittings to "T" and any horizontal sections.
For your safety, the frequency
of cleaning the smoke discharge
system must be determined on the
basis of how the boiler is used.
In case of failure or inadequate cleaning of the
heater may have function problems such as:
• poor combustion
• blackening of the glass
• clogging of grate with accumulation of ash and
pellets
• ash deposit and excessive deposits on the heat
exchanger resulting in poor performance.
46
The operation should be
completed
by
unscrewing
with a screwdriver the fixing
bushings (photo 1). Remove
the
screws
holding
1
1
cleaning kit to the camera
body and pull it completely
(photo 2-3).
2 2
The check of electromechanical components
must be performed only by qualified
personnel with technical knowledge of
electricity and combustion.
the
We recommend that an annual maintenance service
is carried out, preferably under a programmed
service contract. The essential part of this service
is a visual and functional check on the following
components:
• reduction motor
• smoke expulsion fan
3 3
• smoke sensor
• heat-exchanger fan
• ignition sparkplug
• resettable pellet thermostat
• room temperature sensor
• pressostat
• motherboard
• fuse protecting panel - motherboard
These operations must be performed
by a qualified technician, or the
user who will take responsibility
in the event of damage during
maintenance. Perform this maintenance
heater cold and in the absence of electricity.
If such maintenance is performed by
an
authorized
responsibility of the customer.
Surface cleaning
The Boiler is a product by heating, presents the
external sur-faces particularly hot.
For this reason, we recommend extreme caution
when oper-ating in particular:
• Do not touch the Boiler body and the various
components, do not approach the door, it
could cause burns;
• Do not touch the exhaust fumes;
• Do not perform any type of cleaning;
• Do not dump the ashes;
• Do not open the ash tray;
• Be careful that children do not come close.
All cleaning of all parts must be carried out with the
Boiler completely cold and the plug disconnected.
To clean the surfaces, use a rag dampened with
water or with water and a neutral detergent.