5.2
Setting of the display to show cups or litres
The appliance is factory set to display the number of cups.
If you want the display to show litres, you can adjust it as follows:
1. Press the selection button (5.4) and hold it in, then press the start/stop button (5.5) once.
A number will appear in the display.
2. Release both the buttons and then press the start/stop button once again.
3. A "C" (Cups) will appear in the display. Change the "C" to an "L" with the selection button.
4. Now wait for 6 seconds. The adjustment has been saved.
5.3

Setting of the prewet function

This appliance can make coffee using two methods:
Continue-brew ("Cb ") (factory setting); The coffee making process begins immediately and will
pour hot water over the ground coffee without a waiting time. Prewet-brew ("Pb"); part of the
hot water is first poured onto the ground coffee. This causes the coffee to rise so that the
smells and flavours are released. The coffee making process then begins. If you want to set the
appliance to Prewet brew, this setting can be changed as follows:
1. Press the selection button (5.4) and hold it in. Then press the start/stop button once.
A number will appear in the display.
2. Release both buttons and then press the start/stop button twice.
"Cb" (Continue-brew) will appear in the display.
3. Use the selection button to change "Cb" into "Pb" (Prewet-brew).
4. Now wait for 6 seconds. The adjustment has now been saved.
5.4
Setting the water temperature of the water boiler
WARNING
In high altitude areas (> 2000 metres.) the water will boil sooner because of lower
atmospheric pressure. Adjust the temperature of the water boiler, so it will not boil.
The manufacturer is unable to accept any liability for the consequences of altered settings.
On delivery the temperature of the water boiler is set at approx. 90 C.
With the adjustment point (12.3) the temperature of the water boiler can be increased/reduced
within a range of 84 – 98˚C. Use a small screw driver for this. To reduce the temperature, turn
left. To increase the temperature, turn right.