PSU wiring, connection for power supply
The external power supply should be a power supply unit with integrated backup
power supply. The hybrid module is then still supplied with electricity from the batter-
Danger
ies of the unit's backup power supply in the event of a power failure.
The hybrid module does not have a built-in backup power supply.
The hybrid module was designed so that changes to the zone status are detected if
they last at least 400 ms (EN50131-1 Chapter 8.9.1 and EN50131-3 Chapter 8.9 and
Danger
Annex B).
Break-in, intrusion and tampering signals must last at least 400 ms.
The hybrid module was designed so that changes to the fault status (fault signals) are
detected if they last at least 10 s (EN50131-1 Chapter 8.9.1 and EN50131-3 Chapter
8.9 and Annex B).
The software version of the hybrid model is indicated by the LEDs immediately after
the power supply is connected. You can find details on this in the chapter "Software
Note
version displayed by LEDs".
Image 5
Installation
63 |
EN