Hybrid module
connections
C2 (OP2)
(Example variant)
C1 (OP1)
(Example variant)
TR
12 V AUX
0 V
Zone 10
(Example variant)
The hybrid module was designed so that changes to the zone status are detected if
they last at least 400 ms (EN50131-1 Chapter 8.9.1 and EN50131-3 Chapter 8.9 and
Danger
Annex B).
Break-in, intrusion and tampering signals must last at least 400 ms.
The hybrid module was designed so that changes to the fault status (fault signals) are
detected if they last at least 10 s (EN50131-1 Chapter 8.9.1 and EN50131-3 Chapter
8.9 and Annex B).
Observe the sounder power consumption.
If 500 mA at the "0 V / 12 V AUX" output is insufficient, supply the sounder directly
Note
from the PSU. You must then also observe the maximum current output of the PSU.
Note the contact capacity (current, voltage) of the relay.
Sounder connections
Strobe activation
in example
0 V no strobe
12 V strobe active
Sounder activation
in example
0 V no sounder
12 V sounder active
TR
Tamper output of the sounder
in example
0 V no tampering
12 V tampering
when not in use jumper to 0 V
12 V IN
0 V IN
1 - Fault output
Switch closed: OK
Switch open: Fault
Note the zone wiring
Secvest alarm panel program-
ming
Output 402
Output type: e.g. "External strobe"
Output 401
Output type: e.g. "External sounder"
No programming needed.
When this input is activated, the
alarm panel signals "H/M x sounder
tamper" (hybrid module X sounder
tamper)
Zone 410 (example variant)
Zone type: "Fault external sounder"
Installation
69 |
EN