Installation
PSU connections
10.5 - 15 V DC OUT
1 - tamper PSU (if available)
Switch closed: OK
Switch open: Tamper
2- fault 230 V (if available)
Switch closed: OK
Switch open: Fault 230 V
3 - fault empty battery (if available)
Switch closed: OK
Switch open: Battery fault
Make sure the power supply unit cables are connected with the correct polarity.
Note
The wired zone type can be configured separately for each hybrid module.
The wired zone type applies to all 10 or 5 zones/inputs of the respective hybrid mod-
Note
ule.
You can configure this setting in installer mode -> components -> hybrid module.
You can configure the zone programming (type, name, partitions, properties) in in-
staller mode -> components -> HyMo zones
Note
64 |
EN
Hybrid module connections
0 V / 12 V IN
Z5 (example variant)
Zone 405
Zone type: Tamper
Programming is performed on the alarm
panel
Note the zone wiring.
MAINS FAIL
otherwise jumper
LOW BATT
otherwise jumper