Functions and displays

Error and tamper monitoring

The hybrid module continually monitors error and tamper states and reports all events to the alarm
panel. The following is monitored:
• Tamper contact:
The hybrid module's tamper contact is continually monitored.
• Supply voltage:
The hybrid module monitors the supply voltage under load conditions and reports faults to
the alarm panel.
• Supervision
The hybrid module continually sends supervision messages to the alarm panel
• Signal jamming:
The hybrid module monitors attempts to jam the wireless signal. If jamming is detected, the
message "Signal jamming" is sent to the alarm panel.
• Load on the voltage outputs.
The self-repairing fuse will react in the event of excessive currents.
Check the power consumption and whether the consumer is properly con-
Danger
nected.

Time conditions

The hybrid module was designed so that changes to the zone status are detected if they last at
least 400 ms (EN50131-1 Chapter 8.9.1 and EN50131-3 Chapter 8.9 and Annex B).
Break-in, intrusion and tampering signals must last at least 400 ms.
The hybrid module was designed so that changes to the fault status (fault signals) are detected if
they last at least 10 s (EN50131-1 Chapter 8.9.1 and EN50131-3 Chapter 8.9 and Annex B).

Factory Defaults

If the hybrid module is paired with the alarm panel again, it discards all previous links. This causes
the hybrid module to return to the factory default.