Observe the polarity of the output, normal or inverted (Secvest programming) in con-
junction with the type setting low or high (wAppLoxx Control programming) combined
Note
with the plus and minus wiring.
1)
Observe the wAppLoxx Control power consumption.
If 500 mA at the "0 V / 12 V AUX" output is insufficient, supply the wAppLoxx Control
Note
directly from the PSU. You must then also observe the maximum current output of the
PSU.
Observe the permissible voltage range of the wAppLoxx Control.
12 V +/-10% = 10.8 V - 13.2 V
You may need to use a separate power supply unit for the wAppLoxx Control.
Note the contact capacity (current, voltage) of the relay.
Note
You can configure the outputs (type, name, partitions, polarity, options) in installer
mode -> outputs -> HyMo outputs
Note
Observe the wiring of the relay NO/COM or NC/COM (wAppLoxx Control) in conjunc-
tion with the type switch on or switch off (wAppLoxx Control programming) combined
Note
with the property of the wired zone, inverted or not inverted (Secvest programming).
4.
Note the zone wiring
The wired zone type can be configured separately for each hybrid module.
Note
The wired zone type applies to all 10 or 5 zones/inputs of the respective hybrid mod-
3)
ule.
You can configure this setting in installer mode -> components -> hybrid module.
You can configure the zone programming (type, name, partitions, properties) in in-
staller mode -> components -> HyMo zones
Note
The wire loop in Z8 is used for tamper monitoring of the connection cable between
the Secvest alarm panel and wAppLoxx Control.
Note
4)
Installation
73 |
EN