Power consumption,
nominal
Power consumption, typi-
cal
Displays
Connections
Screw terminal TB1
Connections
Screw terminal TB2 and
TB5
Connections
Screw terminal TB3 and
TB4
Standby current
35 mA @ 12 V DC
Defined by:
RX on, without aux load, without loudspeaker, no zones and inputs
connected, Relay OP 1-4 off
0.42 W
0.42 W x 24 h x 365 = 3.68 kWh per year
Standby current
10 zones for 2-wire CC
Mains Fail, Low Batt and TR-0 V (jumpers)
Total
2 status LEDs
TX and TEST: for software status, transmission signalling and test
0 V / 12 V IN
Power supply connections for the external power supply unit
with reverse polarity protection
MAINS FAIL
2 inputs, connection to the isolated network failure output
(switch) on the external power supply unit
LOW BATT
2 inputs, connection to the isolated output "low battery"
(switch) on the external power supply unit
-LS+
Loudspeaker
minimal impedance: 16 ohms
maximum electricity on activation: +270 mA
@ maximum volume
@16 ohms
0 V / 12 V AUX
4 x, 0 V 12 V (nominal) voltage output
maximum 500 mA total
Fuse 500 mA, self-resetting fuse (self-repairing)
Z1 to Z10
Wired zones
10
2-wire FSL/DEOL 2k2/4k7
Technical data
35 mA
+7 mA
+3 mA
45 mA