Technical data
Tamper protection (de-
tection/protection)
Energy supply type
Voltage monitoring
Operating voltage
Power consumption,
maximum
Power consumption,
maximum
52 |
EN
Type B (EN 50131-3:2009 Section 8.7)
Hybrid module and external power supply
Type A (EN 50131-1:2006 + A1:2009 + A2:2017 Section 9 and EN
50131-6:2017 Section 4.2) for external power supply via power sup-
ply unit and batteries as a backup power supply.
Type B (EN 50131-1:2006 + A1:2009 + A2:2017 Section 9 and EN
50131-6:2017 Section 4.2) for external power supply via power sup-
ply unit and batteries as a backup power supply.
Power supply compliant with EN 50131-1:2006 + A1:2009 + A2:2017
9.2 and EN 50131-6:2017 when using an external power supply
which meets these requirements, if installed correctly together with
Secvest FUAA50xxx.
During operation with an external power supply, a fault report is
sent to the alarm panel as soon as it
• indicates a main power supply fault (MAINS FAIL)
• indicates a backup power supply fault (LOW BATT)
• supplies a too-low direct current
o The voltage for a fault is nominally
10.0 V with a tolerance of around +/- 0.5 V.
The user is informed.
10.5-15 V DC, 12 V nominal (external power supply unit)
I DC maximum:
100 mA @ 12 V DC
defined by:
Standby current
10 zones for 2-wire CC
Mains Fail, Low Batt and TR-0 V (jumpers)
Relay OP1-4 ON
Total
TX on
Loudspeaker, maximum volume, @16 ohms
without aux load
35 mA
+7 mA
+3 mA
+55 mA
100 mA
+5 mA
+270 mA