Commands and Accessories

If not installed, safety devices with NC contacts must be jumpered at the COM terminals, or disabled by modifying
the parameters
,
N.A. (Normally Open) .
N.C. (Normally Closed).
CONTACT
9 (COR)
10
12(LAM)
11(COM)
13(ES)
11(COM)
14(+24V)
11(COM)
16(+SC)
15(COM)
16(+SC)
15(COM)
18(FT2)
15(COM)
19(FT1)
15(COM)
56
,
,
,
and
.
DESCRIPTION
Output (potential free contact) for connecting courtesy light.
eter
Input for connecting electric lock, 12 Vdc max. 15 W
Power feed for external devices. See technical characteristics.
Connection for gate open indicator lamp.
The function of the indicator lamp is determined by parameter
Photocell test connection
Set the parameter
Each time a command is received, the control unit switches the photocells off and on to
check that the contact changes state correctly.
Power feeds for all external devices may be connected to reduce battery consumption (if
batteries are used). Set
WARNING! If contact 16 (SC) is used for the photocell test function or battery saving
function, a gate open indicator lamp cannot be connected.
Input (NC) for connecting photocells FT2
The photocells FT2
. Photocell FT2 disabled when gate is opening.
. Photocell FT2 disabled when gate is closing.
. The gate opens when an open command is received if photocell FT2 is
obstructed.
If the photocells are not installed, jumper the terminals 15(COM) - 18(FT2) or set the
parameters
and
WARNING! Use R90/F4ES, G90/F4ES or T90/F4S series photocells.
Input (NC) for connecting photocells FT1
The photocells FT1
. Photocell triggers only during gate closure. Photocell is ignored during gate
opening.
. Movement is reversed if the photocell is triggered during gate closure.
. The gate opens when an open command is received if photocell FT1 is
obstructed.
If the photocells are not installed, jumper the terminals 19(FT1) - 15(COM) or set the
parameters
and
WARNING! Use R90/F4ES, G90/F4ES or T90/F4S series photocells.
duty cycle 50%).
to enable the test function.
or
.
.
.
.
.