Parameters Menu - Roger Technology B70/2DC Instructions Et Consignes Pour L'installateur

Masquer les pouces Voir aussi pour B70/2DC:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 90
10

Parameters menu

VALUE
Selecting automation system model
WARNING! If this parameter is not set correctly, the automation system may not function properly.
N.B.: in the event of a reset to restore the default parameters, this parameter must be set again manually.
Automatic closure after time pause (from gate completely open)
Disabled.
From 1 to 15 of gate closure attempts after photocell is triggered.
Once the number of attempts set is reached, the gate remains open.
Automatic gate closing after mains power outage
Disabled. The gate does not close automatically when mains power is restored.
Enabled. If the gate is NOT completely open, when mains power is restored, the gate closes after a 5
The gate closes in "position recovery" mode (see chapter 16).
Selecting step mode control function (PP)
Condominium function: the gate opens and closes after the set automatic closing time.
The automatic closing timer restarts if a new step mode command is received.
Step mode commands are ignored while the gate is opening. This allows the gate to open completely and
prevents the gate from closing when not required.
If automatic closing is disabled (
manoeuvre
Condominium function: the gate opens and closes after the set automatic closing time.
The automatic closing timer does NOT restart if a new step mode command is received.
Step mode commands are ignored while the gate is opening. This allows the gate to open completely and
prevents the gate from closing when not required.
If automatic closing is disabled (
manoeuvre
), the condominium function automatically attempts a closing
.
), the condominium function automatically attempts a closing
.
).
47

Publicité

Table des Matières
loading

Table des Matières