Roger Technology B70/2DC Instructions Et Consignes Pour L'installateur page 49

Masquer les pouces Voir aussi pour B70/2DC:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 90
Adjusting stop advance of LEAF 1 when opening
Adjusting stop advance of LEAF 2 when opening
The leaf stops against the opening stop.
A leaf stop advance of 1 to 15 motor turns before the completely open position may be set.
Setting automatic closing time
The timer starts from the gate open state and continues for the set time. Once the set time is reached,
the gate closes automatically. The timer count restarts if a photocell is triggered.
Pause time settable from 00 to 90 s.
Pause time settable from 2 to 9 min.
Adjusting opening delay of MOTOR 2
From 0 to 10 s.
Adjusting closing delay of MOTOR 1
From 0 to 30 s.
Setting reverse time after activation of sensing edge or obstacle detection
(crush prevention)
This sets the reverse manoeuvre time after activation of the sensing edge or the obstacle detection
system.
From 0 to 60 s.
Enable electric lock
Disabled.
Enabled. When LEAF 1 approaches the gate closed stop, the controller delivers supplementary power to
Enabled. When LEAF 1 approaches the gate closed stop, the controller delivers maximum power to
Setting motor torque
Increasing or decreasing the value of the parameter increases or decreases motor torque and, as a result,
adjusts obstacle detection sensitivity.
Use values below
SOLO
weather conditions (strong winds or very cold temperatures).
In installations with gate leaves of different lengths, they torque value may be set separately, setting a
value for parameter
between
and
.
(reduced motor torque = increased sensitivity).
05= 0%.
06= +8%; 07= +16%; 08= +25%; 09= +35% (increased motor torque = reduced sensitivity).
Setting obstacle impact force sensitivity MOTOR 1
If the reaction time to obstacle impact force is too long, reduce the value of the parameter. If the impact
force exerted on obstacles is too high, reduce the value of parameter
.
Low motor torque:
01 = minimum obstacle impact force ... 10 = maximum obstacle impact force
N.B.: only use these settings if the medium motor torque values are not suitable for the installation.
Medium motor torque. Recommended setting for adjusting force settings correctly.
11 = minimum obstacle impact force ... 19 = maximum obstacle impact force.
Maximum motor torque. May only be used if the gate is equipped with a sensing edge.
49

Publicité

Table des Matières
loading

Table des Matières