Pentair SIATA SFE-EV PRO Manuel D'utilisation page 27

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 36
The SFE-EV PRO controller features a diagnostic mode, where the service data and historic are stored and
displayed. These data can be helpful for troubleshooting in case of system malfunction.
To access the diagnostic mode, press and hold the
the regeneration button to scroll from one parameter to the next one.
Data
1
xxxx
2
SAxx
3
FFxx
4
M3xxxxxx.xx *
5
Hxxxxx *
6
LMxxxx or M3Hxxxx *
7**
Xx:xx
01
M xx
02
01
02
03
04
05
A xx
8**
06
07
08
09
01
S xx
02
-xx
9
UM 1-7
rExxxxxx*
10
MLMxxxx or MMHxxxx* The flow rate measured in Modular Mode in Liters/min or M3/h
11
12
Mhxxxx
13
AAA.Y
* Parameters L,H, LH and MM are displayed in a rolling string in order to allow a number containing 5 or more
digits to be read.
Data on the time and date of the latest regenerations are present only if regenerations have been carried out.
Statistics may be deleted in the statistics menu. When the first parameter is displayed (number of
regenerations carried out), press and hold down the
0 and the message CLS flashes on the display for a few seconds.
Description
Number of regenerations carried out.
Number of regenerations remaining before triggering the salt alarm.
Number of days elapsed since the last regeneration.
Water treated in M3.
Number of hours elapsed since first installation.
Average consumption since first installation in Liters/min or M3/h.
Time and date of past regenerations. When this data is displayed, some sectors light up**.
Regeneration was launched in instantaneous manual mode
Regeneration was launched in delayed manual mode at the programmed time
Automatic regeneration launched in timed mode (SH:00)
Automatic regeneration launched in combined mode (SH:01) because volume exhausted.
Automatic regeneration launched in combined mode (SH:01) because maximum number of days
for obligatory regeneration has been reached
--
Automatic regeneration launched in volume mode (SH:02)
Automatic regeneration launched in volume mode (SH:02) because maximum number of days
for obligatory regeneration has been reached
--
Automatic regeneration launched in interval mode (SH:03)
Automatic regeneration launched in time clock mode (SH:04)
Regeneration started instantaneously by remote start
Regeneration started at programmed time by remote delayed start
Number of days elapsed since the previous regeneration
Water consumption average(M3 or L) for each day (evaluated considering the last 4 weeks)
Reserve for the current day in Liters or M3
How long (in hours) the flow rate in Modular Mode remains over the programmed threshold
Software version and revision.
Page 27
arrow for 3 seconds. Once in diagnostic mode, press
button for 5 seconds; the statistical data are reset to

Publicité

Table des Matières
loading

Table des Matières