5.
Troubleshooting
i
If some of the actions suggested in this chapter cannot be performed, contact customer
Error code
Messages
1001
RECOVERY
Service Timeout
1002
RECOVERY
High pressure shutdown
1003
RECOVERY
Used Oil bottle full
1004
RECOVERY
Refrigerant cylinder full
1005
RECOVERY
Used Oil Bottle Not Found
2001
VACUUMING
High Pressure in vehicle. Perform
Recovery
2002
VACUUMING
Leak detected
3001
OIL RECHARGE
Service Timeout
3002
OIL RECHARGE
High pressure in vehicle - Perform
Recovery
3003
OIL RECHARGE
High pressure in vehicle - Perform
Vacuuming
3004
OIL RECHARGE
Insufficient Oil Quantity
3005
OIL RECHARGE
High pressure in system
3006
OIL RECHARGE
Fresh oil Bottle Not Found
4001
UV DYE RECHARGE
Service Timeout
4002
UV DYE RECHARGE
High pressure in vehicle - Perform
Recovery
4003
UV DYE RECHARGE
High pressure in vehicle - Perform
Vacuuming
4004
UV DYE RECHARGE
Insufficient UV Dye quantity
4005
UV DYE RECHARGE
High pressure in system
4006
UV DYE RECHARGE
Used Oil Bottle Not Found
5001
R134a
RECHARGE
Service Timeout
5002
R134a RECHARGE
Insufficient R134a quantity
5003
R134a RECHARGE
Less refrigerant in internal bottle
or leakage/blockage in hoses
5004
R134a RECHARGE
High Pressure shutdown
Robert Bosch GmbH
Actions
Check for blockage in the vehicle A/C system
Check for blockage in the vehicle A/C system.
R Empty the used oil bottle.
R Perform scale reset
R Weight limit reached. Reduce quantity of refrigerant in internal refrigerant cylin-
der.
R Load cell is defective. Replace the load cell.
R Check if the used oil bottle is disconnected. If the bottle is disconnected, con-
nect the bottle.
The pressure is greater than 1400 mbar while vacuuming
R Press "Yes" to continue the recovery.
R Press "No" to abort the operation.
R After 24 hours, use the UV torch to detect the leakage in the vehicle A/C system.
Leakage detected in the vehicle A/C system.
R Repair the vehicle A/C system.
Contact customer service.
The pressure is greater than 1400 mbar while recharging.
R Perform recovery
The pressure is greater than 900 mbar while recharging.
R Perform vacuuming
R Oil quantity is less than 30 ml. Refill the oil.
R Reset the fresh oil bottle scale
Perform vacuuming
R Check if the fresh oil bottle is disconnected. If the bottle is disconnected, con-
nect the bottle.
R Check for blockage in the
hoses.
R Check for oil load cell.
R Replace the load cell.
The pressure is greater than 1400 mbar while recharging.
R Press "Yes" to continue the recovery.
R Press "No" to abort the operation.
The pressure is greater than 800 mbar while recharging.
R Press "Yes" to continue the vacuuming.
R Press "No" to abort the operation.
R UV dye quantity is less than 30 ml. Fill the UV dye bottle.
R Reset the UV dye bottle scale.
Perform vacuuming
R Check if the used oil bottle is disconnected. If the bottle is disconnected, con-
nect the bottle.
R Check for blockage in the ACS 651/751.
R Check if quick couplers are open.
Fill the internal refrigerant cylinder
R Check if HP and LP quick couplers are open
R Check the HP and LP service hoses for blockage
R Fill the internal refrigerant cylinder (see chapter 4.10)
R Check the connection to the high pressure switch
R Check if the hose connection to the blue valve on the cylinder is open.
R Check for blockage in the LP hose.
Troubleshooting | ACS 651/751 | 93