110 | ACS 651/751 | Program description
6.13.2
Executing recovery when the engine and the
A/C system are OK
i
After executing step 19 of chapter 6.13.1, the follow-
ing screen is displayed.
1. Follow the instructions on the screen and press E.
 The following screen is displayed.
2. Follow the instruction on the screen and press E.
 The recovery phase is initiated.
i
After the oil drain is completed, the following
screen is displayed.
|
1 689 988 238
2012-11-06
i
The recovery phase continues till the absolute
pressure is 600 mbar. When the recovery is com-
pleted, other service phases are executed auto-
matically.
 After the filling phase is completed, the "Hose
Drain" screen is displayed.
i
If any error occurs during recovery, vacuuming or oil/
UV dye recharge phases, the automatic mode will not
proceed to the filling phase and the "Hose Drain"
screen will not be displayed.
Caution - Risk of frostbite!
If refrigerant escapes, there is a risk of
frostbite to the hands and body.
Carefully disconnect filling hoses as all
hoses can contain pressurized refrigerant.
i
See chapter 6.5.1 and execute steps 21 to 25 to
complete the service.