Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EQ 2100

UTILITY PROGRAMMES

Utility programmes are available only in NORMAL mode.
Selecting the imbalance display resolution
The machine has two wheel imbalance display resolutions. The two resolutions are defined as
X1 (high
resolution) and X5 (low resolution). The resolution with which the imbalances of the wheel are
displayed varies depending on the unit of weight as indicated in table T8.1.
Table T8.1 Display resolution
Set resolution
X1
(high resolution)
X5
(low resolution)
To view the imbalance in X1 resolution (high resolution) press [F+P1]. The machine will display
the message visible in Figure F8.1.0a for one second and the LED next to the button will turn
on. Imbalance values are now displayed in X1 resolution (high resolution).
Fig. F8.0a Enabling of the imbalance display in high resolution.
To return to viewing in X5 resolution (low resolution) press [F+P1] again. The machine will
display the message visible in Figure F8.0b for one second and the LED next to the button will
turn off. Imbalance values are now displayed in X5 resolution (low resolution).
Selection of the static imbalance display
To view the static imbalance, press [F+P2]. The machine will show the static imbalance
value on the display as seen in figure F8.1 and the LED next to the button lights up.
68
AUTOMATIC WHEEL BALANCER 3D DIGITAL DISPLAY
+LASER POINTER
Imbalance unit of measure Display resolution
Grams
Ounces
Grams
Ounces
Fig. F8.0b Disabling imbalance view in high resolution.
1 gram
0,1 ounce
5 grams
0,25 ounces
Notes
The X5 resolution is set by
default at start-up

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Eq 1000