EQ 2100
UFc Converter voltage-frequency test
The converter voltage-frequency test shows two numbers on the displays that represent the
values of the
internal conversion to the CPU-C1 electronic control circuit board. These values are used by
technical support personnel to determine the functioning state of the circuit board. To exit the
test programme, press [F+P9].
Ret Returns to the Service mode
This Test Programme menu option sets the machine back to the SERVICE mode
Error codes
The machine reports error conditions by showing an error code on the display. The list of the error
codes is shown in table T10.1.
Table T10.1 – Error codes
Error code
Description
000 to 009 Machine parameters
010
Reverse rotation of the wheel
011
Wheel speed too low
The wheel cannot be stopped at the end of
012
the launch
013
Wheel speed too high
014
The wheel does not spin
015
Keys pressed or jammed at start-up
Distance sensor not in rest position when the
016
machine is switched on
Width sensor not in rest position when the
017
machine is switched on
018
Reserved
019
Communication processor failure
Lack of communication with the eeprom
020
memory
Lack of machine calibration data or incorrect
021
calibration data
022
Pick-up channel A too high
023
Pick-up channel A too high
024
Pick-up channel A too high
Presence of weight during the Cal0 calibration
025
phase
A launch without weight or failure of the pick-
026
up A signal in the Cal2 calibration phase.
AUTOMATIC WHEEL BALANCER 3D DIGITAL DISPLAY
+LASER POINTER
SIGNALS
Notes
Contact technical support.
Contact technical support.
Check the mains voltage. If the checks do not lead
to any results, contact technical support.
Check the mains voltage. If the checks do not lead
to any results, contact technical support.
Contact technical support.
Contact technical support.
Release all buttons, then turn off or restart the machine.
If the error persists, contact technical support.
Set the sensor to its rest position: the error should
disappear.
If the error persists, contact technical support.
Set the sensor to its rest position: the error should
disappear.
If the error persists, contact technical support.
Turn the machine off or on. If the error persists,
contact technical support.
The machine can still be used but all functions related
to the USB port are disabled.
Turn the machine off and then on again. If the error
persists, contact technical support.
Carry out calibration for the CAR/SUV Wheel Type
and/or for the MOTOWheelType. If the error persists,
contact technical support.
See also ERR030 and ERR031.
Excessive imbalance or anomaly. Turn the machine
off and then on again. If the error persists, contact
technical support
Excessive imbalance or anomaly. Turn the machine
off and then on again. If the error persists, contact
technical support
Excessive imbalance or anomaly. Turn the machine
off and then on again. If the error persists, contact
technical support
Remove the weight and repeat the launch of the Cal0
phase. If the error persists, contact technical support
Apply the intended weight and repeat the launch. If
the error persists, contact technical support.
75