EQ 2100
Dia Test and/or calibration of the Diameter sensor. This programme allows checking the correct
functioning of the automatic acquisition of the wheel's diameter. The automatic wheel diameter
acquisition system requires calibration. Ret Returns to the Service mode. This Test Programme
menu option sets the machine back in the SERVICE mode
[P2] Not used
This button is not currently used in Service mode.
[P3] Machine calibration
This button allows accessing the machine's calibration procedure as described in detail in chapter
4 Machine
calibration.
[P4] Select grams/ounces
By pressing this button, the machine alternates the unit of measure of the wheel weight: if the
unit of measure selected is in grams, select ounces and vice versa. This selection is maintained
even when the machine is shut-down.
The unit of measurement selected will be displayed for one second.
[P5] Select inches/millimetres
By pressing this button, the machine alternates the unit of measure of the wheel dimensions: if
the unit of measure selected is in inches, select mm and vice versa. This selection is maintained
even when the machine is shut-down.
The unit of measurement selected will be displayed for one second.
[P6] Select the imbalances view threshold
This button allows editing the imbalances view threshold. This procedure is intended for technical
support
personnel and is not described in this manual.
[P9] Not used
This button is not currently used in Service mode.
[F+P1] Not used
This button is not currently used in Service mode.
[F+P2] Select weight material in Fe/Zn, or Pb
Use this button to select the balancing weight material. The options available are listed in table
T9.1. The selection of the material type slightly changes the balancing results because the weights
in Iron/Zinc are lighter than those in Lead and therefore are larger.
The machine takes account of these differences when calculating the imbalance.
Tableau 9.1. Balancing weights materials
Option
Type
of
weight material
Fe
Iron or Zinc
Plomb
Pb
Lead
72
AUTOMATIC WHEEL BALANCER 3D DIGITAL DISPLAY
+LASER POINTER
balancing
Notes
This material has been set by default.
Les masses en plomb sont interdites dans certains pays, dont ceux de la
Communauté européenne.
In some countries (such as those of the European Com- munity), Lead weights
are prohibited by law.