Automatic acquisition of the wheel dimensions for the STD and ALU1,2,3,4,5,Programme Types
To introduce the wheel size automatically, proceed as follows:
Machines with Width sensor
1. Assemble the wheel on the shaft;
2. Extract both sensors and rest them on the rim as shown in Figure 3.6;
3. Wait to hear the long acquisition beep and then set the sensors back to the rest position. During
acquisition, the distance and diameter values are shown on the display.
Note: the width is not displayed during automatic acquisition but to verify the newly acquired value,
simply press
[P2].
It is possible to extract the Width sensor alone and view the width that refers to the last distance acquired
(manually or automatically), but there will be no acquisition in this case. However, if you also extract the
distance/diameter sensor, the display with the width will be removed and the acquisition as described in
point 3 will start.
Machines without the Width sensor
1. Assemble the wheel on the shaft;
2. Extract the Distance/Diameter sensor and place it on the rim as shown in Figure F3.6.
3. Wait to hear the long acquisition beep and then set the Distance/Diameter sensor back to the rest
position;
4. Introduce rim width manually. The width of the rim is normally printed on the rim itself.
Alternatively, use the appropriate width measuring
gauge.
Figure F3.6. Automatic data
acquisition in the STD, ALU1,2,3,4,5
programmes
Automatic acquisition of the wheel dimensions for the ALS1 and ALS2 Programme Types
To automatically enter the dimensions of the wheel in the ALS1 and ALS2 Programme types, proceed as
follows:
1. Assemble the wheel on the shaft;
2. Extract the Distance/Diameter sensor and place it on the plane chosen as the internal plane. The point
of support differs depending on whether the ALS1 or ALS2 programme has been enabled. See figures
F3.7 and F3.8;
3. Wait to hear the long acquisition beep and then set the sensor back to the rest position;
4. Extract the Distance/Diameter sensor and place it on the plane chosen as the external plane. See figure
F3.9;
5. Wait to hear the long acquisition beep and then set the sensor back to the rest position;
6. The dimensions of the wheel have been acquired and the values can be displayed and/or modified
by pressing [P1] for the di1/di2 values (internal/external plane distance) and [P3] for the da1/da2values
(internal/external diameter plane).
AUTOMATIC WHEEL BALANCER 3D DIGITAL DISPLAY