Conditions for trouble-free operation:
Except for the mains cable, use shielded cables only.
l
The shield must be carefully connected to PE.
l
Connect motor and mains PE conductors to separate PE terminals.
l
A
B
C
C
D
D
Abb. 1-20
0
Mains cable L1, L2, L3, PE
1
PE connection - mains cable
2
PE connection - motor
3
Shielded control cable
4
Shield connection for control cable (screw shield to shield sheet)
5
PE connection - terminal strip X2
6
Isolated terminal (e.g. star point for motor star connection)
7
Function module
X1
Terminal strip - mains connection
X2
Terminal strip - motor connection
PES
HF shield connection by connecting the shield with a surface as large as possible to PE
L
Wiring according to EMC requirements
X1
I
I
EDK82MV222 DE/EN/FR 3.0
Motor mounting
X2
F
G
G
H
8200mot101
3
Shield connection
1. Prepare cable
2. Route the cable
through the eyebolt
of the shield and
bend the eyebolt.
3. Tighten the screw.
The shield must be
tightly connected to
the shield sheet.
0.7 Nm
6 lb-in
PES
21