Lenze 8200 Motec Instructions De Montage page 107

Masquer les pouces Voir aussi pour 8200 Motec:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

All manuals and user guides at all-guides.com
Code
No.
Name
C0002*
Parameter set
s
transfer using the
keypad
u u u u S S S S E E E E r r r r
(cont.)
(cont )
C0002*
Saving of own
s
settings
u u u u S S S S E E E E r r r r
(cont.)
L
Possible settings
Lenze
Choice
Keypad
-70-
With Application I/O
-10-
With all other function modules
Keypad
-71-
With Application I/O
-11-
With all other function modules
Keypad
-72-
With Application I/O
-12-
With all other function modules
Keypad
-73-
With Application I/O
-13-
With all other function modules
Keypad
-74-
With Application I/O
-14-
With all other function modules
PAR1 ... PAR4
-80-
With Application I/O
-20-
With all other function modules
-9-
PAR1
ð
EDK82MV222 DE/EN/FR 3.0
Commissioning
Code table (excerpt)
PAR1 ... PAR4
ð
PAR1
ð
PAR2
ð
PAR3
ð
PAR4
ð
Keypad
ð
Own settings
7
IMPORTANT
Use the keypad to
transfer parameter sets
PAR1 ... PAR4 to other
controllers
Overwrite all parameter
Overwrite all parameter
sets with corresponding
p
g
k
keypad data
d d t
Overwrite selected
Overwrite selected
parameter set with
p
corresponding keypad
di
k
d
data
data
Copy all parameter sets
Copy all parameter sets
to the keypad
yp
Keypad supports this
function as of version
E82ZC ... BBVB12
You can save your own
basic settings for a
controller (e.g. machine
delivery status):
1. Ensure that
parameter set 1 is
active
2. Controller inhibit
3. Set C0003 = 3,
acknowledge with
v
4. Set C0002 = 9,
acknowledge with
v
, to save your
own basic settings
5. Set C0003 = 1,
acknowledge with
v
6. Enable the controller.
43