Commissioning
7
Linear V/f-characteristic control
Switch-on sequence
12.
Set the V/f-rated frequency (C0015)
Lenze setting: 50.00 Hz
13.
Set the V
boost (C0016)
min
Lenze settings: Depending on the
controller type
14.
If you want to change the settings,
please go to the menu
After parameter setting:
15.
Setpoint selection
16.
Enable the controller.
17.
The drive should now be running at
e.g. 30 Hz
36
U
out
100%
U
min
0
0
E.g. JOG frequencies (C0037,
C0038, C0039), deceleration time
A A A A L L L L L L L L
. ( ¶ 29)
for quick stop (QSP) (C0105) or
motor temperature monitoring
(C0119)
E.g. via potentiometer at terminals
7, 8, 9
EDK82MV222 DE/EN/FR 3.0
f
C0015
d
c
b
e
a
Œ
j g f k i h PS
‚ m n o
p
q
r
Hi
Hz
Lo
Note
The Lenze setting is
suitable for all common
applications
The most important codes
A A A A L L L L L L L L
listed in the menu
are
explained in the code table.
( ¶ 41)
Terminal X3/28 = HIGH
If the drive does not start,
u
press
in addition.