Commissioning
7
Code table (excerpt)
Code
No.
Name
C0052*
Motor voltage
(MCTRL1-VOLT)
C0053*
DC bus voltage
(MCTRL1-DCVOLT)
C0054*
Apparent motor
current
(MCTRL1-IMOT)
C0056*
Unit load
C0061*
Heat sink
temperature
C0084
Motor stator
resistance
C0087
Rated motor
speed
C0088
Rated motor
current
C0089
Rated motor
frequency
C0090
Rated motor
voltage
Motor cos j
C0091
C0092
Motor stator
inductance
C0105
Deceleration time
quick stop (QSP)
C0106
Holding time auto
DCB
C0107
Holding time DCB 999.00 1.00
48
Possible settings
Lenze
Choice
0
0
0
-255
0
0.000 0.000
1390
300
à
0.0
50
10
à
50
à
0.4
0.0
0.0
5.00
0.00
0.50
0.00
= auto DCB not
active
EDK82MV222 DE/EN/FR 3.0
{V}
1000
{V}
1000
{A}
400
{%}
255
{ ° C}
255 Only display
{
}
64.000
{rpm}
16000
{A}
480.0
{Hz}
960
{V}
500
1.0
{mH}
2000.0
{s}
1300.00 Quick stop decelerates
{s}
999.00
= ∞
{s}
999.00
= ∞
IMPORTANT
Only display
Only display
If > +80 °C:
l
– Controller sets
O O O O H H H H
warning
– Chopper frequency
reduced if
C0144 = 1
If > +85 °C:
l
– Controller sets TRIP
O O O O H H H H
depending on the
à
controller
0.0 ... 2.0 x rated output
current of the controller
depending on the
à
controller
depending on the
à
controller
the drive to standstill
according to the
deceleration time set
under C0105. If the
output frequency falls
below the threshold
under C0019, the DCB
will be activated
Holding time, if DCB is
activated because the
value falls below the
setting in C0019.
Holding time, if DCB is
activated via an external
terminal or control word.
L