8.5.3 Display error page
Fig. 32: Error page (status in the event of an
error)
8.5.4 Menu groups
Basic menu
Info menu
Service menu
Error acknowledgement menu
Access disable menu
Installation and operating instructions SIE, DIE, PBE
In some menus, acceptance of the input by pressing the white button
will be confirmed by the brief display of the "OK" symbol.
E000
If an error occurs, the error page will be shown on the display rather
than the status page. The value display shows the letter "E" and the
E.025
three-digit error code separated by a decimal point (Fig. 32).
Basic settings are shown in the main menus <1.0.0.0>, <2.0.0.0> and
<3.0.0.0>, which provide access to set values that may have to be
changed during regular pump operation.
The main menu <4.0.0.0> and its sub-menu elements show measur-
ing data, device data, operating data and current states.
The main menu <5.0.0.0> and its sub-menu elements provide access
to basic system settings for commissioning. The sub-elements are in
a write-protected mode as long as service mode is not activated.
CAUTION! Risk of property damage!
Improper setting changes can lead to pump operation errors, which
can lead to material damage to the pump or system.
• Settings in service mode should only be made during commission-
ing and only by qualified personnel.
In the event of an error, the error page is displayed instead of the sta-
tus page. Pressing the white button from this position opens the error
acknowledgement menu (menu number <6.0.0.0>). Any fault signals
present can be acknowledged after a waiting period.
CAUTION! Risk of property damage!
Errors which are acknowledged without their cause having been
remedied can result in repeated faults, which could lead to prop-
erty damage to the pump or system.
• Only acknowledge errors after they have been remedied.
• Only have faults remedied by qualified personnel.
• If in doubt, consult the manufacturer.
For additional information, see Chapter 11 "Faults, causes and reme-
dies" on page 114 and the error table shown there.
The main menu <7.0.0.0> is only displayed when DIP switch 2 is in the
ON position. It cannot be reached via normal navigation.
In the "Access disable" menu, the access disable can be activated or
deactivated by turning the white button. The change is confirmed by
pressing the white button.