ELEC
ENRICHMENT CONTROL SYSTEM
All manuals and user guides at all-guides.com
POWER BOBBIN
† : Circuit
* : Loaded
ELECTROTHERMAL RAM
8-28
1. Measure:
Power bobbin 1 output peak voltage
Below specification → Replace.
Power bobbin output peak voltage
(Y/B – Y/B)
Cranking
1500
r/min
†
*
†
V
10
7
40
1. Measure:
Electrothermal ram projection length a
Out of specification → Replace.
Measuring steps:
Connect a 12-V battery to the electro-
thermal ram.
Measure the length of the projection
after applying power for five minutes.
Electrothermal ram projection
maximum length:
4 ~ 5 mm (0.16 ~ 0.20 in)
E
3500
*
†
*
30
80
80