9 Switching on
Make sure that the unit and other
components of the installation are closed
so that it is impossible to come into contact
with live parts.
During normal operation the surface of the
illuminator can reach high temperatures.
Do not allow direct contact and position
the appliance where it is inaccessible to
unauthorised persons. Before touching
switch off the illuminator and allow to cool
for a minimum period of 10 minutes.
Do not stay in the vicinity of the device
when it is powered. Act on the device only
in the absence of a power supply.
Make sure that all parts are fastened down
firmly and safely.
The automatic pre-heating (De-Ice) process
could be started whenever the device is
switched on and the ambient temperature
is below 0°C. The procedure is necessary to
guarantee correct operation of the devices
even at low temperatures. The duration
ranges depending on environmental
conditions (from 60 minutes up to 120
minutes).
The unit is switched on by connecting the power
supply.
To switch off the unit disconnect the power.
MNVCU2_2222_EN
10 Configuration
10.1 Default IP address
The unit is configured to obtain an IP
address from a DHCP server.
The IP address acquired via DHCP is visible in the
DHCP server log file.
If the DHCP server is not available, the unit
automatically configures itself with a self-generated
IP address in the 169.254.0.0/16 subnet. Configuring
the IP address of the PC as belonging to the same
subnet (example: IP address: 169.254.1.1, subnet
mask: 255.255.0.0). If auto-allocation fails, the system
automatically sets the address http://192.168.0.100.
Use an ONVIF compatible VMS, the ONVIF Device
Manager application or a network sniffer to find the
IP address of the device (IP scan utility).
10.2 Identification of the MAC
address
The device MAC address is found on the label located
inside the cover of the base connectors, as seen in the
diagram.