10.3.9 Autopan Page
From menu entry Autopan it is possible to specify the
preset autopan start and end.
It is possible to set the speed with which the distance
is to be covered.
Fig. 79
10.3.10 Patrol Page
From menu entry Patrol it is possible to specify the
preset patrol start and end. It is possible to specify
whether the scan of the presets needs to be carried
out randomly or otherwise.
Fig. 80
42
10.3.11 Motions Recall Page
In the Motions Recall menu item, you can specify the
time intervals after which the Pan & Tilt will execute
certain functions.
• Type: This parameter selects the function to
execute once the time interval of inactivity is up.
The functions which can be activated are Home,
Autopan and Patrol.
• Timeout: This parameter specifies the duration of
the inactivity interval.
• Cyclic Re-calibration: This parameter specifies
after how many hours the system must execute
a new axes calibration procedure. Sets value 0 to
disable the function.