6.5
Manual mode
The manual mode can be activated from the standard mode by briefly pressing
the
key.
In the manual mode there is no control: the value of correcting variable last
calculated is a first retained. By pressing the arrow keys, the correcting variable
can be increased or decreased.
With this key you increase the pulse-duty factor of the proportional
valve, i.e. the latter opens up to a max. of 100 %.
With this key you reduce the pulse-duty factor of the proportional
valve.
Press the
will return to the standard mode.
Display in manual mode
Display of actual value
manual mode activated
Fig.: Displayed after switching to the manual mode
Display of the pulse-duty factor of the valve
Fig.: Display of the pulse-duty factor of the valve
NOTE
The display 0 % corresponds to the minimum pulse-duty factor
of the PWM signal set in the menu item VALV : 100 %
corresponds to a pulse-duty factor of 100 %.
18 - 8625-2 Standard