board makes 5 seconds of pre-flashing and it tries to
close. This function is useful to ensure the closure.
The position is unknown after a blackout, so the closing
will be one leaf at a time in "recovering position" mode
(see page 22)
Condominium function (PAR. A4)
If there is a possibility that different users arrive at the
same time, and they push the button of the remote
control in the time that the gate is opening, it is useful to
allow the complete opening to avoid that 2 pushing from
different users cause an inversion of the gate (closing).
If You set the parameter on the value 1 the activation
of the step by step function not causes a closing but it
resets again the pause time.
Deadman (PAR. 07)
The motors are on only throw a continous command,
the command availables are the following: AP and CH;
when You release these command the motors stopped.
Slow-down lenght (PAR. 41, 11, 12)
If the slow-down is enables (PAR.41 different from "0")
You can choice the slow-down length respect to the
total length. On the parameter 41 You can choice 2
different slow-down speed that You can appreciate on
different motors.
ATTENTION! It is necessary make this operation before
to make the learning travel if You do not use the encoder.
If You make this operation after the learning travel, You
have to remake a new programming.
Position tollerance in which the gate it is considered
closed (PAR. 13, 14)
It is shown only if You use and connect the encoder, it
settles the maximum tollerance on the encoder checking
to achieve the point of completely closing in which the
motors stopped.
Recovery margin (PAR. 16)
If You settle the control unit on working time, it is useful
to set a safety margin time (3-4 sec.) to be sure that the
gate will be completely closed, even if there are some
weather changement (wind, low temperature and so
on). When the gate comes back, for example for the
activation of the photocells, it moves back for the exact
time of the previous movement plus the recovery margin
setted (e.g. the gate moves for 5 sec and the recovery
margin is 3, it comes back when a safety is on for 8 sec.
that it is 5 sec. + 3 sec.)
Inversion time after an obstacle (PAR. 27)
It settles how many seconds the motor must be on after
the inversion when it reaches an obstacle, if You setted
a big value it allows a complete inversion.
Start up times (PAR. 36)
The start up manages the motor power at the beginning
and it allows the maximum torque to move the leaf; it
should be useful increase this value depends on the
installation conditions, for example when there is low
temperature.
Release thrust (PAR. 38)
It enables when it is useful to release the electric lock, so
the opening movement is anticipate from a little closing,
You can manage this time with parameter.
If You enables the release thrust it enables automatically
the electric lock (PAR. 28 and 29) in advance for 1 sec.
and the duration times of 3 sec. (this is an automatic
selection, if You want You can change it manually).
If You connect the encoder or the limit switches, the
release thrust is enables only in the case of completely
closed; if You not use encoder or limit switches it runs
each times in opening because the control unit does not
know the exact position of the leafs.
Encoder sensibility to find an obstacle (PAR. 42, 43)
In case of obstacle, the speed decreases till to be
"0", if You setted a low value You make the obstacle
detenction less sensible.
Our standard is setted to be used for all kind of situations,
so its value is small.
If the gate finds an obstacle during his travel, it comes
back immediately.
NOTE: for 6 poles motors You have to set a value less
than 60.
Flashing light setting (PAR. 78)
The flashing light is on when there is a movement, it
is possible to have a continuos activation (for flashing
light with temporized electronic) or You can manage the
blinking throw the electronic (for flashing light without
electronic).
Recover setting default (PAR. 90)
It is possible to recover the setting default, You have to
go to parameter 90 with the button UP and DOWN and
after You have to push togheter the buttons "+" and "-"
for 5+ sec.
ATTENTION!! After this recover, please check if the
parameters are ok for this kind of installation.
Password (PAR. P1...P4 and CP)
If You fill in a password to protect the data memorized,
these datas can be changed only if You know the
password. The steps to fill in the password are the
following:
• Change the value of the parameter P1, P2, P3, P4
• Showing on display the parameter "CP": push togheter
the buttons "+" and "-" for 4 sec. When the display
blinking the password is memorized.
This protection is immediately on if You power off
and power on the control unit or after 10 min. of
inactivity and the display is on stand-by.
ATTENTION!!! When the password is on (the buttons
"+" and "-" not allowed to change the parameter value)