PARAMETER CHANGEMENT
You have to push the buttons UP and DOWN to show
the parameter You want to change, after hou have to
push the buttons + and – to change the value (the right
side value start to blink).
If You continuos to push a button, after 1 second You
will active the fast scrolling, that allows You a fast
changements. To save the value setted on display, You
have to wait some seconds or go to another parameter
with the buttons UP and DOWN: a fast blink of the
display will confirm You the new parameter saved.
NOTE: changements of the parameter value with the
buttons "+" and "-" is possible only when the motor
is stopped, while the readings is always possible.
Table 2 shows the parameter sequency on simply mode.
ATTENTION!!!
Some parameters ("8-" and "b-") are criticals and
their changements when the system runs could be
dangerous and could cause some malfunctioning; these
parameters are showed on the schedule. To make valid
the changements of these parameters, You have to cut
off the power, and after You have to restart the system
and make again the programming of the travel.
RESET OF STANDARD VALUE
NOTE: this set is possible only if You have not fill in the
password on control unit to protect the data.
You have to cut off the power of the control unit, push
together the buttons UP and DOWN, after You have to
give again the power: after 4 seconds the display shows
You the following blinking writing: "rEs-", it means that
You come back at the standard conditions.
CHANGEMENT OF THE FUNCTION MODE
This control unit allows You two different funcion modes:
"extended" or "simple".
On "exetended" mode, the installer can change a lot
of parameters, but he needs a good knowledge of this
product. You have to look the setted schedule at the
end of this instruction.
On the "simple" mode, You can change only few
parameters, to allow a simple installation.
ATTENTION!
This control unit is setted on "simple" mode with
standard parameters who allows You to satisfy a lot
of installations and if You want to go to the "extended"
mode You have to push together the buttons UP and
DOWN for 4 seconds, after the dispaly shows You the
first parameter of "extended" mode:
• You find two decimal points on the first two values on
left side (it shows the parameter number)
• The letter "A" on the number less than 10, to
discriminate the "simple" mode
20
NOTE: You could make this operation several times,
from one mode to the other.
The scheduled of "extended" mode parameter is at the
end of this intruction.
NOTE: the parameter sequency on the "simple" mode
is different from the "extended" one, so please You have
to refer to these instructions or to the label on the box.
FUNCTION MODE: STAND-BY
After 10 minutes of inactitvity, the control unit comes to
the stand-by mode, and the display shows You only a
blinking point.
When the stand-by is on the control unit comes
automatically to the "simple" mode status.
This mode keeps the display at rest, but the control unit
is always ready to execute the commands, to switch on
again the display, You have to push one of the buttons
UP/DOWN or "+,-".
FUNCTION MODE: TEST
You can do that with the button TEST, only if the motors
are stopped, otherwise the TEST button makes a STOP
command, and only if You push again the button TEST
You enter in this function.
The display shows You the following:
name of active input
(showed for 5 seconds)
AP
CH
PP
PE
Or
H70/200AC
SIMPLE MODE
hold buttons
for 4 sec.
EXTENDED MODE
number of safety terminal block on alarm
(blinking, up to safety comes back to the rest)
max
ST
COS1
priority
COS2
FT1
FT2
FCA1
FCC1
minimum
FCA2
priority
FCC2