the CP parameter has the value "01".
Parameters temporary unlock rules: fill in the previous
password on the parameters P1, P2, P3, P4 and after go
to the CP parameter and checking his value, it should
be "00".
It's possible to delete the password, only if you know it,
in this way: insert the password to unlock the "+" and
"EXTENDED" MODE PARAMETERS
TABLE 3
n.
VALORI E DESCRIZIONE
par.
A2 Automatic closing after pause time
0 → OFF not automatic closing
1-15 → numers of reclosing chance
99 → it always reclosing
A3 Automatic closing after blackout
0 → OFF it does not close when the power comes back
1 → ON it closes when the power comes back
A4 STEP BY STEP (PP)
0 → OPEN – STOP – CLOSE – STOP – OPEN - STOP
1 → PP CONDOMINIUM, when it is completely opens, it renews pause time
2 → PP CONDOMINIUM, when it is completely opens, it closes
3 → OPEN – CLOSE – OPEN - CLOSE
4 → OPEN – CLOSE – STOP – OPEN - CLOSE
A5 Preflashing
0 → flashing light starts to flash when the gate moves
1-60 → SECOND anticipate time of preflashing before the gate moves
99 → in opening not enables, 5 seconds preflashing in closing
A6 PP Condominium Pedestrian
0 → OFF pedestrian makes: OPEN – STOP – CLOSE – STOP – OPEN - STOP
1 → ON pedestrian always open
A7 Deadman
0 → OFF normal function
1 → ON the gate moves only if You press the button OPEN and CLOSE
A8 Open gate led (SC)
0 → when the gate is closed the led is switch off, otherwise the led is fixed on
1 → slow flashing in opening, fast in closing and fixed when the gate is completely open, triple flashing
when the gate stopped in the middle of the travel (it repeats every 15 sec.)
2 → SC output is used to power the photocells and to make the photocells test (see pag. 22)
11 Slow-down travel motor 1
1-30 → PERCENTAGE of slow-down travel respect of total travel
12 Slow-down travel motor 2
1-30 → PERCENTAGE of slow-down travel respect of total travel
13 Tollerance of the position in which leaf 1 is consider closed
1-99 → MILLESIMUM respect of total travel
(this parameter is not shown if there are on the limit switches or timing function)
14 Tollerance of the position in which leaf 2 is consider closed
1-99 → MILLESIMUM respect of total travel
(this parameter is not shown if there are on the limit switches or timing function)
15 Lenght of pedestrian travel
1-99 → PERCENTAGE of pedestrian opening respect of total travel
16 Recovery margin for timing functioning
0 → 3 sec.
1 → 6 sec.
21 Pause time before automatically reclosing. When one of the photocells is darkened, the timer of
pause time is stopped, when the beam of photocells is restored the timer starts again the counting
of pause time.
0-90 → SECONDS of pause time before of automatically reclosing
92-99 → from 92 the second number shows You the MINUTES of pause time before of automatically
reclosing (from 2 to 9 minutes)
24
"-" button action, after set the null password P1=00,
P2=00, P3=00, P4=00, and remember to confirm it with
parameter "CP".
If you forget the password please contact the assistance.
H70/200AC
DEFAULT
0
0
0
0
0
0
0
15
15
10
10
99
(2 leafs)
50
(1 leaf)
0
30