22 Working time motor 1
0-99 → SECONDS
It shoes the motor 1 working time (It is not showed if there is on the encoder)
23 Working time motor 2
0-99 → SECONDS
It shoes the motor 2 working time (It is not showed if there is on the encoder)
24 Double working time
0 → OFF
1 → ON
It is not shown if there is on the encoder
25 Opening delay (motor 2)
0-60 → SECONDS
26 Closing delay (motor 1)
0-60 → SECONDS
27 Inversion time after the contact with safety edge or anticrushing
0-99 → inversion SECONDS
28 Anticipate time of electric lock respect on the movement
0-2 → SECONDS
29 Electric lock duration (activation who follows the anticipate time PAR.28)
0-6 → SECONDS
31 Torque level during the normal travel
1-8 → LEVEL
(1 = minimum... 8 = maximum)
32 Torque level during the slow-down
1-8 → LEVEL
(1 = minimum... 8 = maximum)
33 Torque level during the start up
0 → OFF start up not enable
1-8 → ON LEVEL
34 Configuration of start up to avoid the tear on starting
0 → OFF soft start not enable
1 → soft start
2 → slow soft start
35 Torque level of the start up after an inversion due to safety edge or anticrushing
0 → OFF start up not enable, the gate inverts with the torque settled during the normal travel
1-8 → LEVEL
(1 = minimum... 8 = maximum)
36 Start up times
1-20 → SECONDS of the start up torque
38 Release thrust: when it receives an input and the gate is completely closed, it makes a closing for a time
settled and after it opens. It helps a release of electric lock.
0 → OFF it normally starts and it does not make the inversion. The release thrust is not enable
1-4 → SECONDS time of the first closing
41 Slow-down speed
0 → slow-down not enables
1 → slow speed during the slow-down
2 → very slow speed during the slow-down
42 Sensibility to find an obstacle during the normal travel
1-99 → sensibility (1=not sensible ... 99=max sensibility)
ATTENTION: for 6 poles mot set a value less than 60
43 Sensibility to find an obstacle during the slow-down
1-99 → sensibility (1=not sensible ... 99=max sensibility)
49 Automatic reclosing chances after an inversion due to safety edge or anticrushing
0 → NOT automatic reclosing due to safety edge or anticrushing
1-3 → numbers of automatic reclosing chances due to safety edge or anticrushing
50 Behaviour if we interrupt the beam of photocell 1 (FT1) during the opening
0 → IGNORE, it does nothing or FT1 is not installed
1 → STOP, the gate stops until the next input
2 → IMMEDIATELY INVERSION, so it makes a closing
3 → TEMPORARY STOP, when the beam is restored it continues to open
4 → INVERTS when the beam is restored the gates inverts, so it makes a closing
(1 = minimum... 8 = maximum)
H70/200AC
20
20
0
3
5
2
1
3
6
8
8
2
8
3
0
1
20
5
0
0
25