Télécharger Imprimer la page

Roger Technology H70/200AC Instructions Et Avertissements Pour L'installateur page 27

Publicité

Les langues disponibles

Les langues disponibles

74 Configuration of safety edge 2
0 → safety edge 1 OFF or not installed
1 → safety edge 1 SWITCH type, it inverts only in closing
2 → safety edge 1 RESISTIVE 8,2 kOhm type, , it inverts only in closing
3 → safety edge 1 SWITCH type, it always inverts
4 → safety edge 1 RESISTIVE 8,2 kOhm type, it always inverts
Encoder
0 → OFF
75
1 → ON OPTICAL ENCODERS (8 impulse per turn)
2 → ON MAGNETIC ENCODERS(1 impulse per turn)
76 Configuration of 1° radio receiver channel
0 → PP
1 → PEDESTRIAN
2 → OPEN
3 → CLOSE
4 → STOP
5 → COURTESY, the normal functionning is not enable, the relay is only managed by the radio receiver
6 → COURTESY PP, the normal functionning is not enable, the relay is only managed by the radio receiver.
It is like the step by step: on-off-on-off.. the device connected on courtesy light
7 → FLASHING LIGHT, the normal functionning is not enable, the relay is only driven by 1°radio receiver channel
8 → FLASHING LIGHT PP, the normal functionning is not enable, the relay is only managed by the radio
receiver, it is like the step by step: on-off-on-off.. the device connected on flashing light
77 Configuration of 2° radio receiver channel
0 → PP
1 → PEDESTRIAN
2 → OPEN
3 → CLOSE
4 → STOP
5 → COURTESY, the normal functionning is not enable, the relay is only managed by the radio receiver
6 → COURTESY PP, the normal functionning is not enable, the relay is only managed by the radio receiver.
It is like the step by step: on-off-on-off.. the device connected on courtesy light
7 → FLASHING LIGHT, the normal functionning is not enable, the relay is only driven by 2°radio receiver channel
8 → FLASHING LIGHT PP, the normal functionning is not enable, the relay is only managed by the radio
receiver, it is like the step by step: on-off-on-off.. the device connected on flashing light
78 Output configuration of flashing light
0 → FIXED output, the flashing is done through the electronics of the flashing light
1 → 1Hz, the output is on and off 1 time per second (1Hz), the flashing light must be a fixed light one
2 → different flashing for opening and closing, the output is on and off 1 time per second (1Hz) in opening
and 2 times per second (2Hz) in closing, the flashing light must be a fixed light one
79 Courtesy light time
0 → OFF
1 → IMPULSIVE, the output is on for a short time when it starts the movement
2 → the output is on during all movement time
3-90 → SECONDS after the end of the movement, in which the output is on and moreover it is on during
all movement time
92-99 → from 92 the second number indicates the MINUTES after the end of the movement, in which the
output is on and moreover it is on during all movement time (from 2 to 9 minutes)
80 Configuration clock input (ORO), closing the contact it causes an opening of the gate, while the opening of
the contacts causes the closing of the gate. You can choice 2 configurations:
0 → When the clock input (ORO) is closed, it ignores all inputs
1 → When the clock input (ORO) is closed, it accepts all inputs
90 Recall factory settings
After the control unit shows You the parameter 90, You have to push together the buttons "+" and "-" for 5
sec.: the display will show You the word "rES-" blinking, it means that the default value are resetted
n0 Serial number
00-FF → control unit model
n1 Serial number
00-99 → production year
n2 Serial number
00-52 → production week
n3 Serial number
00-99 → 1° progressive number
n4 Serial number
00-99 → 2° progressive number
H70/200AC
1
0
0
1
0
60
0
27

Publicité