51 Behaviour if we interrupt the beam of photocell 1 (FT1) during the closing
0 → IGNORE, it does nothing or FT1 is not installed
1 → STOP, the gate stops until the next input
2 → IMMEDIATELY INVERSION, so it makes an opening
3 → TEMPORARY STOP, when the beam is restored it continues to open
4 → INVERTS when the beam is restored the gates inverts, so it makes an opening
52 When the gate is closed it allows the opening with the beam of photocell 1 (FT1) interrupted
0 → the opening is NOT allowed when the beam of photocell (FT1) interrupted
1 → the opening is allowed when the beam of photocell (FT1) interrupted
2 → when the beam of photocell (FT1) is interrupted, it makes an opening
53 Behaviour if we interrupt the beam of photocell 2 (FT2) during the opening
0 → IGNORE, it does nothing or FT2 is not instsalled
1 → STOP, the gate stops until the next input
2 → IMMEDIATELY INVERSION, so it makes a closing
3 → TEMPORARY STOP, when the beam is restored it continues to open
4 → INVERTS when the beam is restored the gates inverts, so it makes a closing
54 Behaviour if we interrupt the beam of photocell 2 (FT2) during the closing
0 → IGNORE, it does nothing or FT2 is not instsalled
1 → STOP, the gate stops until the next input
2 → IMMEDIATELY INVERSION, so it makes an opening
3 → TEMPORARY STOP, when the beam is restored it continues to open
4 → INVERTS when the beam is restored the gates inverts, so it makes an opening
55 When the gate is closed it allows the opening with the beam of photocell 2 (FT2) interrupted
0 → the opening is NOT allowed when the beam of photocell (FT2) interrupted
1 → the opening is allowed when the beam of photocell (FT2) interrupted
2 → when the beam of photocell (FT2) is interrupted, it makes an opening
56 When the gate is completely open, it closes after 6 seconds if the beam of photocells is interrupted
0 → OFF, an interruption of the beam of photocells when the gate is open does nothing
1 → when the gate is completely open it closes after 6 sec. if there is an interruption of FT1
2 → when the gate is completely open it closes after 6 sec. if there is an interruption of FT2
60 Enables breaking when the gate achieves the limit switch
0 → breaking OFF on limit switch
1 → breaking ON on limit switch
61 Enables breaking due to photocells
0 → breaking OFF on photocells
1 → breaking ON on photocells
62 Enables breaking due to STOP input
0 → breaking OFF on STOP
1 → breaking ON on STOP
63 Enables breaking before an inversion (AP–CH o CH–AP)
0 → NOT breaking before the inversion
1 → breaking before the inversion
64 Breaking time
1-20 → breaking time on DECIMAL SECONDS
65 Breaking force
1-8 → LEVEL
(1 = minimum... 8 = maximum)
70 Motor number
1 → 1 MOTOR
2 → 2 MOTORs
72 Limit switches
0 → OFF
1 → ON
2 → ONLY IN OPENING
73 Configuration of safety edge 1
0 → safety edge 1 OFF or not installed
1 → safety edge 1 SWITCH type, it inverts only in opening
2 → safety edge 1 RESISTIVE 8,2 kOhm type, , it inverts only in opening
3 → safety edge 1 SWITCH type, it always inverts
4 → safety edge 1 RESISTIVE 8,2 kOhm type, it always inverts
26
H70/200AC
2
1
3
4
1
0
0
0
0
0
5
8
2
0
3