TABLE 1
EXTENDED
PARAMETER
50
Enable FT1 also in opening
51
Enable FT1 in closing
52
Obstacle on opening on the motor
53
Enable FT2 on opening
54
Enable on closing
55
Obstacle on opening on the motor
72
Limit switch selection
73
Enable safety edge 1
74
Enable safety edge 2
Table 1 shows some parameters of the extended
version.
PAY ATTENTION!!!
• If the photocells are not installed, and You want to
exclude completely them to avoid to make a jumper
on terminal blocks: You have to set the following
parameters: par.51=0, par.53=0 e par.54=0
• If the safety edges are not installed and You want to
exclude completely them to avoid to make a jumper
on terminal blocks: You have to set the following
parameters: par.73=0 e par.74=0
PLUG-IN RADIO RECEIVER
The radio receiver allows You 2 functions. Our standard
is setted on (see picture 1 on pag.16):
PR1 step by step function (can change it on par.76)
PR2 pedestrian opening function (You can change it on
parameter 77)
DISPLAY FUNCTION - FUNCTION MODE
The display, depends on function mode of the control
unit, can show You the following information:
• COMMAND STATUS MODE / SAFETY: the display
shows You the command input stauts on the two left
side value, the display shows You the safety status on
the two right side value.
• PARAMETER MODE: the display shows You the
parameter number on the two left side value, the
display shows You the value on the two right side
value:
o
Simply mode, for example:
o
Full mode, for example:
The parameter is shown with 2 decimal point lighted on
the full mode and with the word "A" for the parameter
less than 10.
• STAND-BY MODE: the LED "POWER" flashes, it
means that there is tension (decimal point number
on the left side). It passes automatically on stand-by
18
DESCRIPTION
H70/200AC
DEFAULT VALUE
(resetted throw reset function)
0 (ignored)
2 (inversion)
1 (ignored)
3 (stop, and after continuos to open)
4 (stop, e after come back and re-open)
1 (ignored)
0 (not enable – not need a jumper)
3 (contact N.C., it always invertsthe travel)
1 (contact N.C.,it only inverts on closing)
after 10 minutes inactivity on the display buttons.
• TEST MODE: the left side shows the active command
name (for 5 seconds), the right side shows, blinking,
the number of terminal blocks on alarm (00 if there is
not any safety on alarms, so the control unit is able
to execute the commands). There is an exception
when You have a limit switch on, but it not causes
an obstacle to give a command. The safety status
remains on flashing until the alarm is solved; if there
are 2 safeties on alarms, when You solved the first
one, the control unit shows the second one and so on.
FUNCTION MODE: COMMAND AND
SAFETY STATUS
This function mode shows command and safety status
on display segment, see figure 2.
NOT ENABLE SAFETY: the correspondent LED
segment flashing
ABSENT SAFETY: the segment it is never shown (for
example: the limit switches status on motor 2 when it
setted the single leaf is not shown)
FUNCTION MODE: PARAMETERS
PARAMETER
UP
DOWN
PROG
UP
it moves on next parameter
DOWN it moves on previous parameter
+
it increases the parameter value
-
it decreases the parameter value
PROG it programs the working time
TEST
it enables the test status (only if the motors are
stopped, otherwise You have to command the
STOP and only when You push again the button
You can enter in this mode)
VALUE
+
-
TEST