Télécharger Imprimer la page

Roger Technology H70/200AC Instructions Et Avertissements Pour L'installateur page 21

Publicité

Les langues disponibles

Les langues disponibles

It allows to check the commands and the safeties: the
control unit starts the flashing light and the open gate
light for a few seconds on every their activation (terminal
block. nr. 34, "SC").
At the same time the display shows You:
• on fixed word, the command on (on left side, for 5
seconds)
• on blinking number, the safety terminal blocks on
alarm (on right side, up to the safety is on alarm)
After 10 seconds of inactivity, the control unit comes
back at standard mode, showing You the input/safety
status.
If You want to go out immediately from TEST mode, You
have to press again the button TEST.
PROGRAM
ATTENTION !!! Before to make it, You have to check:
• Safeties must be on rest, or make a jumper if they are
not in.
• It is not possible to enter on program mode, if one of
the safety is on alarm; and the display shows You (on
test mode) the alarm input on
• It is not possible to enter on program mode, if
"deadman" is enable (par.A7 = 1)
• The gate must be closed, to avoid the risk on opening
that the leaf 2 crashes the leaf 1
ATTENTION:
• Leaf 1(terminal blocks 4,5,6): it is the first leaf
on opening and the first one that it must achieve a
completely open; it is also the leaf for the pedestrian
opening
• Leaf 2 (terminal blocks 7,8,9): it is the first leaf on
closing
• It is necessary to have a mechanical stop also in
opening, or You have to use the limit switch.
• Working time programming runs during the closing
phase, if You have not encoder and limit switches, You
have to calculate more time than the effiective one
(min. 2 seconds – max 4 seconds after the closing) to
be sure that it will be done even in different weather
conditions.
• Depending on the different motors (arm, underground,
articulated arm; fast or slow) the selection of slow-
down will modify their behavior: for the slow motors (6
poles motors) not use the bigger slow-down (maintain
the setting standard, par.41 = 01)
• If You connect the limit switches, the travel will be
stopped when You achieve these limit switches, the
safety time (on programming without encoder) it is
calculated automatically by the control unit.
• The programmation will be stop and the display
will show you "APP.E" in these cases:
- If You push one of the display buttons, except the
PROG button.
- If a safety is on (photocells, safety edge).
In these cases You have to re-start the programmation.
WORKING TIME PROGRAM
(WITHOUT ENCODER, par.75=00)
To enter in programming set You have to push the button
PROG for 4 sec: the display shows You the word "APP-"
after You can push again the button PROG, or press the
button of the remote control enables to the step by step
function, You can go to the learning program.
First pressure PROG: it starts the opening of the
motor 1 (AP1) and after the delay time it starts to open
automatically also the motor 2 (AP2 showed on the
display for two seconds); the display will show You only
the word AP1 because it is the first leaf will achieves
the mechanical stop and it is the first leaf, that has to
stopped with the second pressure of the PROG button.
Second pressure PROG: when the leaf 1 achieves the
mechanical stop, You have to push the button PROG
to stop the motor 1, the display will show You the word
AP2 because it is the next leaf who has to stop on the
mechanical stop.
Third pressure PROG: when the second leaf achieves
the mechanical stop on opening, You have to make
the same operation made for the leaf 1; the display will
show You blinking the word "PA". After 2 sec. will start
automatically the closing phase, on motor 2 and the
diplay will show You the word CH2.
Fourth pressure PROG: when it passed the delay
time on closing, You have to push the button to start the
closing of leaf 1; the display will show You the word CH1
for 2 sec., after the display will show You again the word
CH2 because it is the first leaf who has to achieve the
mechanical stop on closing.
Fifth pressure PROG: when the leaf 2 achieves the
mechanical stop on closing, we suggest You to wait 3
sec. and after push the PROG button, so You stop the
motor 2 and the display will show You the word CH1
because it is the next leaf who has to stop.
Sixth pressure PROG: when the leaf 1 achieves the
mechanical stop on closing, we suggest You to wait 3
sec. and after push the PROG button, so You can stop
the motor 1: the program is done.
WORKING TIME PROGRAM
(WITH ENCODER, par.75=1/2)
To enter in programming set You have to push the button
PROG for 4 sec: the display shows You the word "APP-"
after You can push again the button PROG, or press the
button of the remote control enables to the step by step
function, You can go to the learning program.
First pressure PROG: the programming will be fully
automated, so wait the end of the learning, avoid to
pass through the photocells.
The display will show You the word "AUTO" and motor
H70/200AC