5.5
installing fl ashing and storm collar
5.6

connection to a masonry chimney

The appliance may be connect-
ed to either a lined or unlined
masonry chimney.
IF THE CHIMNEY IS LINED:
The fl ues must be made of
vitrifi ed clay and be in sizes
of 8" (203.2mm) square or
8" (203.2mm) round (inside
diameters) or 8"x12" [(203.2mm
x 304.8mm)] with a minimum
height of 15 feet (4.6m) above
the appliance.
8" (203.2mm) round fl ues are
recommended.
Installation must conform to both national and local code requirements.
IF THE CHIMNEY IS UNLINED:
A stainless steel liner listed to either Standard ULC-S640M in
Canada or UL-1777 in the USA, must be used. Liners for new
masonry chimneys may be used to connect the appliance to the
chimney. The liner must be continuous from the appliance to the
chimney cap and be installed only per manufacturers instructions.
In both cases, the chimney structure must be supported by angle
iron anchored into the masonry walls. The allowable masonry used
in chimney construction is 3 1/2" (88.9mm) brick, solidly mortared
and must fully encase the fl ue. Ensure there are no leaks.
In no case is the masonry enclosure to be supported by the appliance. Allow a 1" (25.4mm) air cavity for expan-
sion. Use the fl ue tile support accessory, see your local authorized dealer / distributor.
note:
The fl ue tile support is to be suspended on appropriate lintels.
installation
HI-TEMP GASKET
APPLIANCE TOP
FOR A MASONRY APPLIANCE USE A
FLUE TILE SUPPORT. FOR A
PRE-FABRICATED CHIMNEY USE AN
ANCHOR PLATE.
W415-1501 / G / 05.10.22
EN
19