Rates And Efficiencies; Rating Plate Information - Napoleon Plazmafire 48 Manuel D'installation Et Operation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION
Altitude (FT)
Max. Input (BTU/hr)
Min. Inlet Gas Supply Pres-
sure
Max. Inlet Gas Supply
Pressure
Manifold Pressure (Under
Flow Conditions)
* When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specific recommendations from the
local authority having jurisdiction, the certified altitude input rating shall be reduced at the rate of 4% for each additional 1,000ft
(305m) above sea level.
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is suitable for mobile home
installation. The natural gas model can only be installed in a mobile home that is
permanently positioned on its site and fueled with natural gas. This appliance may
be installed in an aftermarket permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases, unless a certified kit is used.
A barrier designed to reduce the risk of burns from the hot viewing glass is
provided with the appliance and must be installed.
Expansion / contraction noises during heating up and cooling down cycles are
normal and are to be expected.
This appliance is equipped with a three-prong (grounding) plug for protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from the plug.
3.4

rating plate information

For rating plate location, see "INSTALLATION OVERVIEW" section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
note:
The rating plate must remain with the appliance at all times. It must not be removed.
DIRECT VENT, VENTED GAS FIREPLACES. APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING
ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE
WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES,
IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND
SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT
APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME
INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A. THIS APPLIANCE MUST BE
INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY; IF NONE, FOLLOW THE CURRENT
ANSI Z223.1, OR CSA B149, INSTALLATION CODES.
FOLLOW THE INSTALLATION INSTRUCTIONS LOCATED IN THE INSTALLATION MANUAL.
MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG)
PRESSION AU COLLECTEUR: 3.5" D'UNE
COLONNE D'EAU(GN)
MIN SUPPLY PRESSURE: 4.5" W.C.(NG)
PRESSION D'ALIMENTATION MIN: 4.5" D'UNE
COLONNE D'EAU (GN)
MAX. SUPPLY PRESSURE: 13" W.C. (NG)
PRESSION D'ALIMENTATION MAX: 13" D'UNE
COLONNE D'EAU (GN)
NOT FOR USE WITH SOLID FUEL. FOR USE WITH GLASS
DOORS CERTIFIED WITH THIS APPLIANCE ONLY.
WARNING:
DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT WITH THE FLAMES,
OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS / DÉGAGEMENTS MINIMAUX DES MATÉRIAUX COMBUSTIBLES *:
MANTEL / CEILING
15"
SIDES
7"
VENT SIDES / BOTTOM
1"
FLOOR
6"
VENT TOP
3"
* SEE INSTALLATION MANUAL FOR FURTHER INFORMATION / VOIR MANUEL D'INSTALLATION POUR PLUS
D'INFORMATION.
SEE OWNER'S INSTRUCTION MANUAL FOR MINIMUM AND MAXIMUM VENT LENGTHS.
RÉFÉRER AU MANUEL D'INSTALLATION DE PROPRIÉTAIRE POUR LES LONGUEURS D'ÉVACUATION MINIMALE
ET MAXIMALE.
WOLF STEEL LTD.
MAX SIZE: 8.5" X 4.75"
HOLE TO BE 0.250"Ø
MATERIAL: CLASS III A-2, PERMANENT LABEL, WATERPROOF, .010MIL VELVET MATTE LEXAN AND/OR .050 HI-TEMP POLYESTER, CAPABLE OF WITHSTANDING A
MAXIMUM TEMPERATURE OF 175°F (79°C).
AND QUALITY!

Rates and Efficiencies

(11mb) w.c.
(32mb) w.c.
CERTIFIED TO / CERTIFIÉ CSA 2.22-2016 AND / ET ANSI Z21.50-2016 VENTED DECORATIVE GAS APPLIANCES / FOYER À GAZ VENTILÉ.
FOR USE WITH BARRIER W565-0273.
9700539 (WSL)
4001658 (NAC)
WHD48N
CWHD48N
0-4500FT (0-1370m)
28,000 BTU/h
19,000 BTU/h
REDUCED INPUT / ALIMENTATION RÉDUITE
70.8%
MANTEAU / PLAFOND
CÔTÉS
CÔTÉS DE L'ÉVENT / ÉVENT INFÉRIEUR
PLANCHER
ÉVENT SUPÉRIEUR
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
general information
NG
0-4,500*
28,000
4.5"
13"
ENGLISH:
3.5"
(9mb) w.c.
FOYER À GAZ VENTILÉ. HOMOLOGUÉ POUR INSTALLATION DANS UNE CHAMBRE À COUCHER, UNE
SALLE DE BAIN ET UN STUDIO. APPROPRIÉ POUR INSTALLATION DANS UNE MAISON MOBILE SI
SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SÉRIE DE
MAISONS MOBILES ÉQUIPÉES AU GAZ, EN VIGUEUR AU CANADA OU AUX ÉTATS-UNIS DE LA
NORME DE SÉCURITÉ ET DE CONSTRUCTION DE MAISONS MANUFACTURÉES, TITRE 24
CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ÉTATS-UNIS NE PEUT ÊTRE
APPLIQUÉE, SE RÉFÉRER A LA NORME RELATIVE AU CRITÈRE DE MESURES DE SÉCURITÉ
CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURÉS, LES
SITES ET LES COMMUNAUTÉS, ANSI/NFPA 501A. CODES. INSTALLER L'APPAREIL SELON LES
CODES OU RÈGLEMENTS LOCAUX, OU EN L'ABSENCE DE TELS RÈGLEMENTS, SELON LES
CODES D'INSTALLATION ANSI Z223.1 OU CSA-B149 EN VIGUER.
BARRIÈRE W565-0273. SUIVEZ LES INSTRUCTIONS D'INSTALLATION SE TROUVENT DANS LE
4001657 (NGZ)
4001659 (WUSA)
MODEL
CWHD48P
ALTITUDE / ÉLÉVATION
0-4500FT (0-1370m)
INPUT / ALIMENTATION
28,000 BTU/h
23,000 BTU/h
P4
70.8%
UN COMBUSTIBLE SOLIDE NE DOIT PAS ÊTRE UTILISÉ
AVEC CET APPAREIL. UTILISER AVEC LES PORTES
VITRÉES HOMOLOGUÉES SEULEMENT AVEC CETTE
APPAREIL.
AVERTISSEMENT:
N'AJOUTEZ PAS À CET APPAREIL AUCUN MATÉRIAU DEVANT ENTRER EN CONTACT
AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.
15"
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE NAPOLEON VENT KITS. SEE OWNER'S INSTALLATION
7"
1"
MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND RESEALING IS NECESSARY AFTER SERVICING THE
6"
VENT-AIR INTAKE SYSTEM. /
3"
L'APPAREIL DOIT ÉVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'ÉVACUATION PROPRE À NAPOLEON. RÉFÉRER AU
MANUEL D'INSTALLATION DE PROPRIÉTAIRE POUR L'ÉVACUATION PRÉCISE. IL EST IMPORTANT DE BIEN RÉINSTALLER
ET RESCELLER L'ÉVENT APRÉS AVOIR ASSURÉ LE MAINTIEN DU SYSTÉME DE PRISE D'AIR.
ELECTRICAL RATING: 115V, 60HZ. LESS THAN 12 AMPERES
SPÉCIFICATIONS ÉLECTRIQUES: 115V, 60HZ. MOINS DE 12 AMPÈRES
DECORATIVE PRODUCT: NOT FOR USE AS A HEATING APPLIANCE
PRODUIT DÉCORATIF: NE PAS UTILISER COMME APPAREIL DE CHAUFFAGE
SERIAL NUMBER/NO. DE SÉRIE:
P
0-4,500*
28,000
11"
(27mb) w.c.
13"
(32mb) w.c.
10"
(25mb) w.c.
70.8%
15
CWHD48
70.8%
15
WHD48
FRENCH:
Cote énergétique des foyers à gaz
70.8%
Basée sur la norme CSA P.4.1-02
15
WHD48
Modèle No.
Cote énergétique des foyers à gaz
70.8%
POUR UNE UTILISER AVEC
MANUEL D'INSTALLATION.
MANIFOLD PRESSURE: 10 INCHES W.C.(P)
PRESSION AU COLLECTEUR: 10" D'UNE
Basée sur la norme CSA P.4.1-02
COLONNE D'EAU (P)
15
WHD48P
MIN SUPPLY PRESSURE: 11" W.C. (P)
CWHD48
PRESSION D'ALIMENTATION MIN: 11" D'UNE
Modèle No.
COLONNE D'EAU (P)
MAX. SUPPLY PRESSURE: 13" W.C. (P)
PRESSION D'ALIMENTATION MAX: 13" D'UNE
COLONNE D'EAU (P)
WHD48
W385-2131 / B
W415-1606 / D / 08.23.18
EN
B
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Whd48nWhd48p

Table des Matières