Napoleon HIGH COUNTRY 6000 Instructions D'installation Et D'utilisation page 30

Masquer les pouces Voir aussi pour HIGH COUNTRY 6000:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

fi nishing
EN
C.
Connect the 6" (152.4mm) collar to the blower opening located on the side of the appliance. An optional
opening is covered on the other side of the appliance. If this location is preferred, switch the cover plate
and collar. Secure by reaching through the collar and bending the tabs.
Use sealant to ensure that the connection is air tight.
note:
We recommend installing the blower in a different room or
even different level of the house. This will generate great
air movement and improve the distribution of the warm air
coming from the appliance.
D.
Electrical Connection
I. Remove the junction box covers on the
appliance and the blower.
II. Removing the junction box cover on the
appliance exposes 4 black, labeled wires:
• 2 wires labelled "by-pass": go to by-pass
(summer) switch (not supplied - overrides the
thermally activated switch enabling the user to
run the blower without heat).
important:
Marrett by-pass (summer) switch wire leads sepa-
rately (do not connect together) if the by-pass switch
is not desired.
• 1 wire labelled "blower": connects to KB-35
rheostat (not supplied) and then fan-speed
control blower wire connects to white blower
wire.
• 1 wire labelled "L1": connects to power (hot
lead).
III. Removing the junction box cover on the
blower exposes 3 coloured wires:
• 1 black wire: connects to power "L2" (neutral
lead).
• 1 green wire: connects to ground.
• 1 white wire: connects to fan-speed control
rheostat (not supplied) (see above).
30