4.5

INSTALLING FLASHING AND STORM COLLAR

Remove the nails from the shingles above and to the sides of
the chimney. Place the fl ashing over the chimney pipe and slide
underneath the sides and upper edge of the shingles. Ensure that
the chimney pipe is properly centered within the fl ashing, giving
a 3/4" (19.1mm) margin all around. Fasten to the roof on the top
and sides. DO NOT NAIL through the lower portion of the fl ashing.
Make weather-tight by sealing with caulking. Where possible, cover
the sides and top edges of the fl ashing with roofi ng material. Apply
waterproof caulking, provided with the fl ashing, around the chimney,
1" (25.4mm) above the top of the fl ashing and push the storm collar
down into the caulking. Insert a rain cap onto the top of the last
chimney section.
4.6

CONNECTION TO A MASONRY CHIMNEY

The appliance may be connected
to either a lined or unlined masonry
chimney.
IF THE CHIMNEY IS LINED:
The fl ues must be made of vitrifi ed
clay and be in sizes of 8"
(203.2mm) square or 8" (203.2mm)
round (inside diameters) or 8"x12"
[(203.2mm x 304.8mm)] with a
minimum height of 15 feet (4.6m)
above the appliance.
8" (203.2mm) round fl ues are
recommended.
Installation must conform to
both national and local code
requirements.
IF THE CHIMNEY IS UNLINED:
A stainless steel liner listed to
either Standard ULC-S640M in Canada or UL-1777 in the USA,
must be used: Liners for New Masonry Chimneys, may be
used to connect the appliance to the chimney. The liner must
be continuous from the appliance to the chimney cap and be
installed only per manufacturers instructions.
In both cases, the chimney structure must be supported by angle
iron anchored into the masonry walls. The allowable masonry
used in chimney construction is 3 1/2" (88.9mm) brick, solidly
mortared and must fully encase the fl ue. Ensure there are no
leaks.
In no case is the masonry enclosure to be supported by the
appliance. Allow a 1" (25.4mm) air cavity for expansion. Use the fl ue tile support accessory, see your local
authorized dealer / distributor.
NOTE: The fl ue tile support is to be suspended on appropriate lintels.
FLUE TILE
HI-TEMP GASKET
FLUE TILE
ANGLE IRON
SUPPORT
TO SUPPORT
CHIMNEY
APPLIANCE TOP
WEIGHT
ANGLE IRON RESTS
ON BRICK SIDE-WALLS,
FREE OF UNIT.
LINED CHIMNEY INSTALL
RAIN CAP
CAULKING
STORM COLLAR
FLASHING
88.1A
LINER
SUPPORT
USE AN 7" (177.8mm)
OR 8" (203.2mm) LINER
WITH A DRIPLESS TYPE
A CONNECTOR
(IF USING 7"
(177.8mm) AN
INCREASER
MUST ALSO
BE USED).
UNLINED CHIMNEY INSTALL
HI-TEMP GASKET
FIREPLACE TOP
FOR A MASONRY FIREPLACE USE A
FLUE TILE SUPPORT. FOR A
PRE-FABRICATED CHIMNEY USE AN
ANCHOR PLATE.
62.4C
W415-1501 / 05.15.15
19
EN
WEATHER
SEALANT