INSTALLING FLASHING AND STORM COLLAR

The following are generic installation instructions for installing the flashing around a chimney. Installation of
all types of factory-built chimney systems is to be in accordance with the chimney manufacturer's
installation instructions. Remove the nails from the shingles above and to the sides of the chimney.
Place the flashing over the chimney pipe and slide underneath
the sides and upper edge of the shingles. Ensure that the
chimney pipe is properly centered within the flashing, giving a
3/4" (19.1mm) margin all around. Fasten to the roof on the top
and sides. DO NOT NAIL through the lower portion of the
flashing. Make weather-tight by sealing with caulking. Where
possible, cover the sides and top edges of the flashing with
roofing material. Apply waterproof caulking, provided with the
flashing, around the chimney, 1" (25.4mm) above the top of
the flashing and push the storm collar down into the caulking.
Insert a rain cap onto the top of the last chimney section.
4.6

AIR COOLED CHIMNEY INSTALLATION

Any air cooled chimney 10" (254mm) or 12" (30.5cm) in
diameter listed to CAN/ULC-S604 for Canada or UL-103 or
for the United States may be installed. Any air cooled chimney
selected for use MUST have provisions to directly feed outside
air to the corresponding anchor plate via sealed housing; for
example, the NZAC10KT that has been developed specifically
for the use with 10" M&G DuraVent DuraChimney II.
NOTE: Follow the chimney manufacturer's instructions for
installing the chimney.
NOTE: Use 111KT outside air kit to connect to air housing.
Maximum length of 4" (101.5mm) liner is 20' (6m). If great-
er length is required then increase the liner diameter to 6"
(152.4mm)
AIR HOUSING
(NZAC10KT)
4" (102mm)
LINER
RAIN CAP
CAULKING
STORM COLLAR
WEATHER
SEALANT
FLASHING
39.13
AIR HOUSING
W415-1676 / A / 03.17.17