5.8.6 INSTALLING FLASHING AND STORM COLLAR

Remove the nails from the shingles above and to the sides of
the chimney. Place the fl ashing over the chimney pipe and slide
underneath the sides and upper edge of the shingles. Ensure that
the chimney pipe is properly centered within the fl ashing, giving
a 3/4" (19.1mm) margin all around. Fasten to the roof on the top
and sides. DO NOT NAIL through the lower portion of the fl ashing.
Make weather-tight by sealing with caulking. Where possible, cover
the sides and top edges of the fl ashing with roofi ng material. Apply
waterproof caulking, provided with the fl ashing, around the chimney,
1" (25.4mm) above the top of the fl ashing and push the storm collar
down into the caulking. Insert a rain cap onto the top of the last
chimney section.
W415-1328 / A / 01.05.16
2 FT
(0.6m)
MIN
10 FT
(3M)
7" (178mm)
OPTIONAL
VENT PIPE
4" (102mm)
"B" VENT
SECURELY
ATTACH VENT
ADAPTER TO
FLUE COLLAR
3 FT
(1m)
MIN
88.1A
RAIN CAP
CAULKING
STORM COLLAR
WEATHER
SEALANT
FLASHING